          當前位置:卓爾瑞華(北京)科技有限公司>>WIKA壓力及溫度儀表>> PGS43.100WIKA PGS43.100 PGS43.160 不銹鋼耐震膜片式微壓電接點壓力表

          WIKA PGS43.100 PGS43.160 不銹鋼耐震膜片式微壓電接點壓力表

          參  考  價面議
          具體成交價以合同協(xié)議為準

          產(chǎn)品型號PGS43.100

          品       牌

          廠商性質(zhì)代理商

          所  在  地北京市

          更新時間:2022-03-27 08:03:23瀏覽次數(shù):388次

          聯(lián)系我時,請告知來自 智能制造網(wǎng)
          WIKA PGS43.100 PGS43.160 不銹鋼耐震膜片式微壓電接點壓力表

          類型: 隔膜壓力表 聯(lián)接型式: G1/2
          型號: PGS43.100 PGS43.160 精度等級: 1.0
          品牌: WIKA/威卡 環(huán)境溫度: -40-70(℃)
          加工定制: 公稱直徑: 100 160(mm)
          測量范圍: 0-250mbar(MPa)    

           

          WIKA PGS43.100 PGS43.160
          不銹鋼耐震膜片式微壓電接點壓力表
          Diaphragm pressure gauge with switch contacts
          Models PGS43.1x0, stainless steel version


          Diaphragm pressure gauge model PGS43.100 with
          switch contact model 831.21


           
           

             Applications
               Control and regulation of industrial processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar
               Monitoring of plants and switching of electric circuits
               For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience
               Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction


             Special features
               High reliability and long service life
               Wide choice of special materials
               Up to 4 switch contacts per instrument
               Also available with liquid-filled case for high dynamic pressure loads or vibrations
               Gauges with inductive contacts for use in hazardous areas with ATEX approval
               Gauges with electronic contact for PLC applications

           

           

           

             Description
              Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the model PGS43.1x0 switchGAUGE can be used.


              Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are
          mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
              The set pointer can be adjusted using a removable adjustment key in the window.

          Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.


              The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.
              As switch contacts magnetic snap-action contacts, reed switches, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.
              For further information on the different switch contacts please see data sheet AC 08.01.

           

             Standard version


             Nominal size in mm
              100, 160


             Accuracy class
              1.6


             Scale ranges
              0 ... 25 mbar to 0 ... 250 mbar (flange Ø 160 mm)
              0 ... 400 mbar to 0 ... 25 bar (flange Ø 100 mm)
              or all other equivalent vacuum or combined pressure and vacuum ranges


             Pressure limitation
              Steady: Full scale value
              Fluctuating: 0.9 x full scale value


             Overpressure safety
              5 x full scale value, however max. 40 bar


             Permissible temperature
              Ambient: -20 … +60 °C
              Medium: +100 °C maximum


             Temperature effect
              When the temperature of the measuring system deviates
              from the reference temperature (+20 °C):
              max. ±0.8 %/10 K of full scale value


             Process connection with lower measuring flange
              Stainless steel 316L, G ½ B (male), 22 mm flats


             Pressure element
              ≤ 0.25 bar: Stainless steel 316L
              > 0.25 bar: NiCr-alloy (Inconel)


             Pressure chamber sealing
              FPM/FKM


             Movement
              Stainless steel


             Dial
              Aluminium, white, black lettering


             Pointer
              Instrument pointer: Aluminium, black
              Set pointer: red


             Case with upper measuring flange
              Stainless steel, with blow-out device in case back
              With safety version: With solid baffle wall (Solidfront) and
              blow-out back


              Window
              Laminated safety glass


             Bezel ring
              Cam ring (bayonet type), stainless steel

           

             Electrical connection
              Terminal box


             Ingress protection
              IP 54 per EN 60529 / IEC 529


             Switch contacts
           

             Magnetic snap-action contact model 821
               No control unit and no extra power supply required
               Direct switching up to 250 V, 1 A
               Up to 4 switch contacts per measuring instrument


             Inductive contact model 831
               Long service life due to non-contact sensor
               Additional control unit required (model 904.xx)
               With corresponding control unit suitable for use in zone 1 / 21 (2 GD) hazardous areas
               Low effect on the indication accuracy
               Fail-safe switching at high switching rates
               Insensitive to corrosion
               Up to 3 switch contacts per measuring instrument


             Electronic contact model 830 E
               For direct triggering of a programmable logic controller (PLC)
               2-wire system (option: 3-wire system)
               Long service life due to non-contact sensor
               Low effect on the indication accuracy
               Fail-safe switching at high switching rates
               Insensitive to corrosion
               Up to 3 switch contacts per measuring instrument


             Reed switch model 851
               No control unit and no extra power supply required
               Direct switching up to 250 V, 1 A
               Also suitable for direct triggering of a programmable logic controller (PLC)
               Free from wear as without contact
               Up to two change-over contacts per measuring instrument


             Switching function
              The switching function of the switch is indicated by function index 1, 2 or 3.
              Model 8xx.1: Contact makes (clockwise pointer motion)
              Model 8xx.2: Contact breaks (clockwise pointer motion)
              Models 821.3 and 851.3: Change over; one contact breaks
                                       and one contact makes simultaneously
                                       when pointer reaches set point
              For further information please see data sheet AC 08.01, electrical switch contacts

           

             Options
               Other process connection
               Sealings (model 910.17, see data sheet AC 09.08)
               Liquid filling (filling liquid silicone oil M50, ingress protection IP 65)
               Overpressure safety: 10 x full scale value, max. 40 bar
               Vacuum safe to -1 bar
               Max. medium temperature +200 °C
               Higher indication accuracy, class 1.0 and 0.6
               Open connecting flanges per DIN/ASME from DN 15 to DN 80 (preferred nominal widths DN 25 and 50 or DN 1" and 2"; see data sheet IN 00.10)
               Wetted parts lined/coated with special materials such as PTFE, Hasloy, Monel, nickel, tantalum, titanium, silver (gauges with accuracy class 2.5)
               Inductive contacts also in safety version (SN, S1N)

           

             Instruments with special approvals 1)
               Pressure switch per VdTÜV code of practice 100
               SIL2 approval
               DVGW declaration for the use in gas supply systems
               DIN/DVGW registration: Pressure switch per EN 1854
               Gost standard approval (Russia)
               Design approval for connection to hazardous zone 0
             1) Specification on request

           

             Dimensions in mm
              switchGAUGE model PGS43.100 with switch contact model 821, 831 or 830 E

           

           

                   

                  switchGAUGE model PGS43.100 (safety version) with switch contact model 821, 831 or830 E
                 

              switchGAUGE model PGS43.160 with switch contact model 821, 831 or 830 E

             

              switchGAUGE model PGS43.160 (safety version) with switch contact model 821, 831 or 830 E

             

              switchGAUGE model PGS43.063 with switch contact model 851.3 or 851.33

             

              switchGAUGE model PGS43.160 with switch contact model 851.3 or 851.33

             

              Ordering information
              Model / Nominal size / Type of contact and switching function / Scale range / Connection size / Options

           

           




           