精品乱码一区内射人妻无码-亚洲中文AⅤ中文字幕在线-免费不卡国产福利在线观看-国产综合无码一区二区色蜜蜜

          廣州市朝德機電設備有限公司

          MDI水銀接觸器

          參  考  價:面議
          具體成交價以合同協(xié)議為準

          產品型號

          品牌

          廠商性質經銷商

          所在地廣州市

          更新時間:2017-08-18 17:46:45瀏覽次數(shù):1333次

          聯(lián)系我時,請告知來自 智能制造網
          廣州市朝德機電設備有限公司


          :鄭杰克、向
          : novosor : www.novosor.com
          地址:廣州市越秀區(qū)朝天路66號3F
          業(yè)代理
          BDI 水銀接觸器

           

          廣州市朝德機電設備有限公司


          :鄭杰克、向
          : novosor     : www.novosor.com
          地址:廣州市越秀區(qū)朝天路66號3F

          業(yè)代理  
          Relay Pics and Drawings * Price quote form *
          * Mercury Spill Kit *
           

          Pictures and drawings of MDI Relays
          Click here to see our drawings.
           
          Relay Information
          • General Information
          • Features
          • Typical Applications
          • Description
          • 30 AMP Normally Open Contactors
          • 35/60 AMP Normally Open Contactors
          • 100 AMP Contactors
          • "S" 100 AMP Contactors
          • High Voltage Contactors
          • Coil Data
          • Proper Fusing is Required

           

          GENERAL INFORMATION

          Mercury Displacement Relays are all designed and built to meet the most exacting demands of industry. They have won their high place in the electrical field by doing the tough and tricky jobs that ordinary equipment could at best do in an uncertain manner. They have proved their ability to stand up under the most adverse conditions of temperature, dust and moisture, in all types of applications. All the care required for the manufacture of high-grade instruments is used in the manufacture of the switches. All switch parts are specially cleaned, and contamination is avoided by use of tweezers, gloves, etc., when making assemblies.

          Contactors are hermetically sealed with high quality glass to metal seals.
          The stainless steel tube is totally encapsulated in high grade UL approved epoxy to prevent moisture damage and voltage breakdown through the protective coating.
          The coils are wound on compact nylon bobbins and molded onto the metal tube to provide minimum power loss. This allows for low coil power required to actuate the contactor. This also enables the units to handle high loads with minimum derating due to higher ambient temperatures.
          Inert gases internally prevent excessive arcing between the mercury and the electrodes which enables the unit to function for millions of cycles with very low contact resistance, and minimum deterioration of the internal parts.
          Available in all standard coil voltages, in single, two and three pole arrangements. Other coil voltages available upon request.
          In multiple pole units each tube is actuated by its own coil. This eliminates pull-in variation between contact tubes, assuring consistent switching.


          Back to the top

           
          FEATURES
          1. ADVANTAGES OVER ELECTROMECHANICAL AND SOLID STATE RELAYS
            1. Superior Performance and Reliability
              1. Long life
              2. Durable
            2. Compact Size
            3. Low, Predictable Contact Resistance
            4. Reduced RFI for Improved Interface Capability
            5. Handles a Variety of Loads
              1. Increases design flexibility
            6. Rapid On-Off Cycling Capability
              1. Mercury quickly dissipates contact heat
            7. Low Coil Power Requirements
            8. Minimal Derating Due to Higher Ambient Temperatures
            9. Quiet Action
          2. DESIGN and CONSTRUCTION
            1. Contacts are within a hermetically sealed steel body
              1. Impervious to adverse conditions
              2. No external arcing
            2. Arcing is in a gaseous atmosphere
              1. Quenches the arc
              2. Extends relay life
            3. Only one moving part (the plunger)
              1. No buttons to pit, weld or burn out
            4. One coil for each set of contacts
              1. Assures consistent switching
              2. Minimizes pull-in variation between contacts
            5. Epoxy encapsulated
              1. Moisture resistant
              2. High dielectric strength
              3. Permanently fixes contacts to coil; eliminating possible misalignment
              4. Helps dissipate heat and noise
              5. Rugged (impact resistant)
          3. BENEFITS
            1. Reduction of Operational and Maintenance costs
            2. Increases Utilization and Productivity of Equipment
              1. By reducing down-time
            3. Installation and service is a routine operation
              1. Simple to install
              2. No sophisticated equipment is required
              3. Easy to trouble-shoot

          Back to the top
          TYPICAL APPLICATIONS
          FOR MDI's MERCURY DISPLACEMENT CONTACTORS
           
          LIGHTING

          Auditorium Lighting
          Copy Equipment
          Dimmer Controls
          Display Signs
          Emergency Lighting
          Flood Lights
          High Intensity Lamps
          Hospital Lighting
          Lighting Test Panels
          Mercury Vapor Lamps
          Parking Lots
          Photography Lighting
          Scoreboards
          Sodium Vapor Lamps
          Stage Lighting
          Street Lighting
          Tower Control
          Traffic Signal
          Tungsten Lamps
          GENERAL APPLICATIONS

          Air Conditioning
          Alarm Systems
          Automatic Door Closers
          Battery Chargers
          Blue Print Machines
          Copiers
          Computer Power Supplies
          Corrosive Locations
          Dusty, Oily Locations
          Dry Cleaning Equipment
          Energy Management Systems
          Farm Incubators and Brooders
          High Cycle Rate Applications
          Low Voltage Switching
          Marking Equipment
          Engraving Equipment
          Motor Starting
          Soldering Systems
          ephone Switching
          Test Panels
          Vapor Degreasers
          X-Ray Machine Controls
          ELECTRIC HEATERS

          Baseboard Heaters
          Blow Molding
          Cabinet Heaters
          Chemical Tank Heaters
          Curing Furnaces
          Drying Ovens
          Duct Heaters
          Film Packaging
          Glass Furnaces
          Heat Lamps
          Heat Sealing Machines
          Induction Heater
          Industrial Ovens
          Infrared Heaters
          Ink Drying
          Ink Heating
          Injection Molding Machines
          Kilns
          Lab Ovens
          Packaging Equipment
          Plastic Extruders
          Quartz Heaters
          Radiant Heaters
          Roof Top Heating
          Shrink Tunnels
          Unit Heaters
          Vacuum Forming


           
           
          FOOD INDUSTRY EQUIPMENT
          (HEATERS)


          Baking Ovens
          Coffee Urns
          Deep Fryers
          Dishwashers
          Electric Grills
          Electric Ranges
          Pizza Ovens
          Steam Generators
          SPECIALTY APPLICATIONS


          Capacitor Discharge Systems
          Hazardous Locations
          Phase Converters
          Tower Control

          Back to the top
          DESCRIPTION

           
          MERCURY TO METAL CONTACTOR:

          The load terminals are isolated from each other by the glass in the hermetic seal. "The plunger assembly", which includes the ceramic insulator, the magnetic sleeve and related parts, floats on the mercury pool. When the coil is powered causing a magnetic field, the plunger assembly is pulled down into the mercury pool which is in turn displaced and moved up to make contact with the electrode, closing the circuit between the top and bottom load terminal, which is connected to the stainless steel can.

          To make the unit function as a "Hybrid" time delay, we add a solid state circuit to the coil to delay the power to the coil.

          For constant duty applications, a return spring is used in place of the buffer spring. Contact the factory.


          Back to the top
          30 AMP Normally Open Contactors

           
          General Information:

          The 30 AMP model is designed to save space and simplify mounting methods. The standard mounting bracket on the three pole model allows the unit to be mounted in standard 3" snap track channel. If you do not use snap track mounting, the standard three pole bracket has key hold slots for easy mounting in any panel arrangement. The universal three pole mounting bracket has various mounting holes and key hole slots to meet a variety of mounting centers.

          The 30 AMP series is a more compact line with a well proven switch, which is the heart of mercury relays. It is the same switch design that is in our 35 and 60 AMP encapsulated MDRs, which have withstood the test of time and millions of cycles in many different applications.

          Typical Specifications:
           

          • On Normally Open Units:
            • Operate Time: 50 milliseconds
            • Release Time: 80 milliseconds
          • Contact Resistance: 30 AMP = .003 ohm *
          • Dielectric Withstant: 2500 VAC RMS
          • Longevity: Millions of Cycles
          • Temperature Range: -35 degrees C to 85 degrees C
          • Coil Terminals: #6 Binding Head Screws
          • Load Terminals: #8 Binding Head Screws
          • UL Listing: File #E62767
          • C.S.A.: File #LR41198
          * After Cycling Under Load
           
          Coil Data
          Catalog No.Res. (Ohms)Current (MA)VAWatts
               
          30NO-24D
          230NO-24D
          330NO-24D

          30NO-24A
          230NO-24A
          330NO-24A

          3020A
          23020A
          33020A

          30NO-220A
          230NO-220A
          330NO-220A
          180
          131
          73

          28
          12.5
          7.6

          725
          317
          210

          3,150
          1,300
          728
          133
          188
          329

          316
          610
          815

          65
          118
          163

          27
          56
          86
          3.2
          4.5
          7.9

          7.6
          14.6
          19.6

          7.8
          14.2
          19.6

          6.0
          12.3
          18.9
          3.2
          4.5
          7.9

          2.8
          4.7
          5.0

          3.1
          4.4
          5.6

          2.2
          4.1
          5.5
           
          RATINGS
          (Ratings are in amps unless otherwise specified.)
           
          Type of LoadsVoltage30NO
             
          A.C. Resistive



          A.C. IND. P.F. .4 OR GREATER



          GENERAL PURPOSE P.F. .7
          OR GREATER


          D.C. RESISTIVE HEATING




          TUNGSTEN LAMP

          SINGLE PHASE
          MOTOR LOADS


          THREE PHASE
          MOTOR LOADS

           
          240V
          480V
          600V

          120V
          240V


          240V
          480V


          48V
          125V
          250V


          120V

          120V
          240V


          240V
          480V
          30
          30
          30

          -
          -


          -
          -


          -
          -
          -


          -

          -
          -


          -
          -

          Back to the top
          35/60-AMP Normally Open Contactors

           
          Typical Specifications:
          • On Normally Open Units:
            • Operate Time: 50 milliseconds
            • Release Time: 80 milliseconds
          • On Normally Closed Units:
            • Operate Time: 30 milliseconds
            • Release Time: 35 milliseconds
          • Contact Resistance:
            • 35-AMP = .003 ohm *
            • 60-AMP = .002 ohm*
          • Dielectric Withstand: 2500 Vac Rms
          • Longevity: Millions of Cycles
          • Temperature Range: -35 degrees C to 85 degrees C
          • Coil Terminals: #6 Binding Head Screws
          • Load Terminals: Pressure Connectors for A.W.G. #4 - #14 on 35-AMP Units and A.W.G. #2 - #8 on 60-AMP Units
          • UL Listing: File #E62767 for 35 and 60-AMP N.O. Units 1-4 Poles
          • C.S.A.: File #LR41198 for 35 and 60-AMP N.O. Units (Heater Loads) 1-3 Poles
          • Auxiliary Devices for Use in Hazardous Locations. UL File #E71867 N.O. Units Approved for Class 1, Groups A, B, C and D, Division 2 Only. To Order for Hazardous Locations, Add the Suffix -X to Part Number.
          * After Cycling Under Load


          RATINGS
          (Ratings are in amps unless otherwise specified.)

          Type of Loads
          A.C.
          RESISTIVE



          A.C.IND. P.F.
          .4 OR GREATER


          GENERAL PURPOSE
          P.F. .7 OR GREATER


          D.C.
          RESISTIVE HEATING



          TUNGSTEN LAMP


          SINGLE PHASE
          MOTOR LOADS


          THREE PHASE
          MOTOR LOADS

          240V
          480V
          600V


          120V
          240V


          240V
          480V


          48V
          125V
          250V


          120V


          120V
          240V


          240V
          480V
          35NO
          35
          35
          35


          -
          -


          -
          -


          -
          -
          -


          35


          1H.P.
          1H.P.


          -
          -
           
          35NO(H)
          35
          35
          -


          25
          15


          -
          -


          35
          16
          12


          35


          2HP
          3HP


          5HP
          7.5HP
          35NC
          35
          35
          -


          25
          15


          35
          35


          35
          16
          12


          35


          2HP
          3HP


          5HP
          7.5HP
          60NO
          60
          60
          48


          -
          -


          -
          -


          -
          -
          -


          60


          -
          -


          -
          -
          60NO(H)
          60
          60
          -


          30
          20


          60
          60


          60
          40
          20


          60


          3HP
          5HP


          7.5HP
          10HP
          60NC
          60
          60
          -


          30
          20


          60
          60


          60
          40
          20


          60


          3HP
          5HP


          7.5HP
          10HP

          Back to the top
          100-AMP Contactors
          Typical Specifications:
          • On Normally Open Units:
            • Operate Time: 50 milliseconds
            • Release Time: 80 milliseconds
          • On Normally Closed Units:
            • Operate Time: 45 milliseconds
            • Release Time: 60 milliseconds
          • Contact Resistance: .001 ohm *
          • Dielectric Withstand: 2500 Vac Rms
          • Longevity: Millions of Cycles
          • Temperature Range: -35 degrees C to 85 degrees C
          • Coil Terminals: #6 Binding Head Screws
          • Load Terminals: Pressure Connectors. Standard Accepts A.W.G. #2 to #12. For A.W.G. #1 to #8, Add Suffix -5 to Catalog No. (I.E. 10020A-5)
          • Ratings: Derate over 240 Vac Res.
          *After Cycling Under Load


          RATINGS
          (Ratings are in amps unless otherwise specified.)

           

          Type of LoadsVoltage100NO100NO(H)100NC
               
          A.C. RESISTIVE240V100100100
           480V808080
           600V707070
           
           
             
          A.C. IND.
          P.F. .4 OR GREATER
          120V-100100
           240V-100100
           
           
             
          GENERAL PURPOSE
          P.F. .7 OR GREATER
          240V-10080
           480V-8080
           
           
             
          D.C. RESISTIVE HEATING48V-100100
           125V-5050
           250V-3030
           
           
             
          TUNGSTEN LAMP120V100100100
           
           
             
          SINGLE PHASE MOTOR LOADS120V-7.5HP7.5HP
           
           
             
          DOUBLE PHASE MOTOR LOADS240V-10HP10HP
           
           
             
          THREE PHASE MOTOR LOADS240V-15HP15HP
           480V-20HP20HP

          Back to the top
           

          "S" 100 AMP Contactors
           
          Typical Specifications:
          • On Normally Open Units:
            • Operate Time: 50 milliseconds
            • Release Time: 80 milliseconds
          • On Normally Closed Units:
            • Operate Time: 45 milliseconds
            • Release Time: 60 milliseconds
          • Contact Resistance: .001 ohm *
          • Dielectric Withstand: 2500 Vac Rms
          • Longevity: Millions of Cycles
          • Temperature Range: -35 degrees C to 85 degrees C
          • Coil Terminals: #6 Binding Head Screws
          • Load Terminals: Pressure Connectors. Standard Accepts A.W.G. #1 to #8
          • Ratings: Derate over 480 VAC Res.

          * After Cycling Under Load

           


          RATINGS
          (Ratings are in amps unless otherwise specified.)

           

          Type of LoadsVoltage"S" 100NO"S" 100NO(H)
              
          A.C. RESISTIVE240V100100
           480V100100
           
           
            
          GENERAL PURPOSE
          P.F. .7 OR GREATER
          240V100100
           480V100100
           
           
            
           

          Back to the top
           

          High Voltage Contactors
           

          For UV Curing, and Various High Voltage applications. Available in Single Pole, Normally Open, and Normally Closed Units. The coils utilize 6-32 Wire Binding Screws, and the Contacts use Compression type terminals for #4 thru #14 AWG wire.
          Ratings are: 10 Amps @ 3,500 VAC
          15 Amps @ 2,500 VAC
          AC Inductive - Power Factor .7 or Greater



          Coil Data
           
          Catalog NumberCoil VoltageResistanceCurrent DrawWattageV.A.
          100NC-24D-6A24VDC121198 ma4.84.8
          100NC-120A-6A120VAC380125 ma5.915.0
          100NC-220A-6A220VAC1,40076 ma8.116.7
          1002DH-6A12VDC16750 ma9.09.0
          100NO-24AH-6A24VAC16760 ma9.218.2
          100NO-24DH-6A24VDC65370 ma8.98.9
          10020AH-6A12-VAC380158 ma9.519.0
          100NO-220AH-6A220VAC1,40090 ma11.319.8

          Back to the top
           

          Coil Data
          Per pole ratings on standard coils

           

           

          Catalog NumberVoltageResistance
          (D.C. Ohms)
          Current
          (Milli-amperes)
          Volt Amperes
          (V/A)
          Power
          (Watts)
          35NO-24A24VAC502425.82.9
          3520A120VAC1,250536.43.5
          35NO-208A208VAC3,400306.23.1
          35NO-220A220VAC4,800286.23.8
          35NO-277A277VAC7,900205.53.2
          35NO-480A480VAC20,000125.93.0
               
           
          35NO-6D6VDC134622.82.8
          352D12VDC363334.04.0
          35NO-24D24VDC1761363.33.3
          35NO-48D48VDC636753.63.6
          3525D125VDC3,400374.64.6
          35NO-250D250VDC14,800174.24.2
               
           
          35NC-24A24VAC363107.43.5
          35NC-120A120VAC860657.83.6
          35NC-220A220VAC3,400316.83.3
               
           
          35NC-12D12VDC363334.04.0
          35NC-24D24VDC1761363.33.3
          35NC-48D48VDC560864.14.1
          35NC-125D125VDC3,400374.64.6
               
           
          60NO-24A24VAC502596.23.4
          6020A120VAC1,250485.82.9
          60NO-208A208VAC3,400306.23.1
          60NO-220A220VAC4,800275.93.5
          60NO-277A277VAC7,900195.32.9
          60NO-480A480VAC20,000125.82.9
               
           
          602D12VDC363334.04.0
          60NO-24D24VDC1761363.33.3
          60NO-48D48VDC636753.63.6
          6025D125VDC3,400374.64.6
          60NO-240D250VDC14,800174.34.3
               
           
          60NC-24A24VAC363257.85.3
          60NC-120A120VAC860698.34.1
          60NC-220A220VAC3,400347.53.9
          60NC-277A277VAC7,900267.35.5
               
           
          60NC-12D12VDC363334.04.0
          60NC-24D24VDC1401714.14.1
          60NC-48D48VDC560864.14.1
          60NC-125D125VDC3,400374.64.6
               
           
          100NO-24A24VAC1664615.56.7
          10020A120VAC38013716.47.1
          100NO-220A220VAC1,4007316.17.5
          100NO-277A277VAC2,4005515.27.3
          100NO-480A480VAC6,3003516.87.7
               
           
          100NO-24D24VDC653698.98.9
          100NO-48D48VDC3501376.66.6
          10025D125VDC2,400526.56.5
               
           
          100NC-24A24VAC1651512.44.2
          100NC-120A120VAC38011013.24.6
          100NC-208A220VAC1,4005511.44.2
          100NC-240A240VAC1,6854911.84.0
          100NC-480A480VAC6,3002713.04.6
               
           
          100NC-12D12VDC284335.25.2
          100NC-24D24VDC1211984.84.8
          100NC-48D48VDC3801266.16.1
          100NC-125D125VDC2,400526.56.5

           


          Notes:
          1. Inrush Current=1.5 times the steady state current. (No inrush on DC coils).
          2. Minimum operating voltage 90% of nominal voltage.
          3. All A.C. voltages are at 50/60 Hz.
          4. For other coil voltages, contact factory.
          5. Ratings shown are per pole (Coils are in parallel).

          Back to the top
           

          Proper Fusing is Required
          • While MDIs contactors handle high inrush, such as lamp loads, very well, mercury contactors are susceptible to damage by short circuit currents, and should be fused to minimize short circuit fault currents. Fast acting UL class RK-1 and class J fuses and semiconductor I2t fuses more effectively protect relays than other fuses. These are low-peak fuses designed to limit short circuit currents. Regardless, when there is a short circuit, relay operations should be closely monitored afterward because of the possibility of concealed damage that could cause the relays to behave inconsistently.

          RECOMMENDED

          250VOLT600VOLT
          KTN-RKTS-R
          JJN/A3TJJS
           JKS/A4J
           KTK-R
          • Mercury Displacement relays must mount vertically +/- 10 degrees.
          • Control line can be protected with metal oxide varistor (MOV). Use suffix -11.
          • Disconnect power before installing or servicing. Observe all electrical and safety codes and ordinances such as National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

          Back to the top

          MEGACON隔離繼電器 MARZOCCHI 齒輪泵 GHP

          廣州市朝德機電設備有限公司$r$n$r$n: $r$n:鄭杰克 : n

          德Meder磁簧繼電器

          廣州市朝德機電設備有限公司$r$n$r$n: $r$n:鄭杰克 : n

          德MESSOTRON位移傳感器、放大器,編碼器

          廣州市朝德機電設備有限公司$r$n$r$n: $r$n:鄭杰克 : n

          會員登錄

          ×

          請輸入賬號

          請輸入密碼

          =

          請輸驗證碼

          收藏該商鋪

          X
          該信息已收藏!
          標簽:
          保存成功

          (空格分隔,最多3個,單個標簽最多10個字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時間回復您~

          以上信息由企業(yè)自行提供,信息內容的真實性、準確性和合法性由相關企業(yè)負責,智能制造網對此不承擔任何保證責任。

          溫馨提示:為規(guī)避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

          撥打電話
          在線留言
          榆林市| 阿拉善左旗| 新河县| 孙吴县| 大田县| 巢湖市| 休宁县| 灵武市| 南皮县| 莱芜市| 阿坝| 如皋市| 分宜县| 乐亭县| 邻水| 大同县| 福建省| 永兴县| 冷水江市| 涞水县| 滦平县| 莒南县| 木里| 千阳县| 读书| 宜川县| 焦作市| 自治县| 上犹县| 新宁县| 垫江县| 邵阳市| 南木林县| 青河县| 永新县| 高安市| 巴林右旗| 娱乐| 胶南市| 桃园市| 南通市|