精品乱码一区内射人妻无码-亚洲中文AⅤ中文字幕在线-免费不卡国产福利在线观看-国产综合无码一区二区色蜜蜜

          深圳市灣邊貿(mào)易有限公司

          當前位置:深圳市灣邊貿(mào)易有限公司>>醫(yī)療模體>> 711-HN頭部專業(yè)代理進口CIRS公司711-HN頭部及診斷模體

          專業(yè)代理進口CIRS公司711-HN頭部及診斷模體

          參  考  價:面議
          具體成交價以合同協(xié)議為準

          產(chǎn)品型號711-HN頭部

          品牌

          廠商性質(zhì)代理商

          所在地深圳市

          更新時間:2016-08-15 05:34:16瀏覽次數(shù):307次

          聯(lián)系我時,請告知來自 智能制造網(wǎng)
          深圳灣邊貿(mào)易公司

          深圳灣邊貿(mào)易美國CIRS公司711-HN頭部及診斷模體*!

          廠家:CIRS 美國

          型號:711-HN

          深圳灣邊貿(mào)易公司    

          深圳灣邊貿(mào)易美國CIRS公司711-HN頭部及診斷模體*!

          廠家:CIRS 美國

          型號:711-HN

           

          Dental Cone Beam Realistic Maxillofacial Phantom

          ATOMmax Diagnostic Head Phantom 

          Model 711-HN

          Our Most Realistic Maxillofacial Phantom

          Features:

          • Includes detailed anatomical features
          • Frankfurt plane identified to ensure proper alignment
          • Tissue Equivalent from 50 keV to 25 MeV
          • Positioning stand with six degrees-of-freedom
          • Carrying case included
          • 4 year warranty

          The CIRS Dental and Diagnostic Head Phantom is a standard of reference for diagnostic radiology of the head. The phantom is designed to assist technical and clinical staff in the selection, monitoring, training and verification of scanning parameters common to most radiological procedures requiring fine anatomical details.

          The Model 711-HN provides a consistent tool for researchers, clinicians and technologists. It is ideal for determining optimum system settings, commissioning new equipment, monitoring system performance and training in dental X-ray, panoramic X-ray, CT and cone beam CT procedures.

          The phantom includes an adjustable stand for positioning within a cone beam CT or panoramic X-ray system. The jaw of the phantom is slightly opened and front teeth are vertically aligned to replicate correct positioning with a bite guide. Please note that an actual bite guide can not be positioned in this product.

          The Phantom is constructed of proprietary tissue equivalent materials. ATOM®MAX is made of tissue simulating resins that mimic the X-ray attenuation properties of human tissue for both CT and therapy energy ranges (50keV-25 MeV). The Model 711-HN approximates the average male human head in both size and structure. The phantom includes detailed 3D anthropomorphic anatomy including brain, bone, larynx, trachea, sinus, nasal cavities and teeth. The bones contain both cortical and trabecular separation. The teeth include distinct dentine, enamel and root structure including the nerve. The sinus cavities are fully open.

           

          ATOMmax Model 711-HN Phantom
          Model 711-HN Phantom
          ATOMmax 3D CT Reconstruction 
          3D CT Reconstruction
          ATOMmax Sagittal View 
          Sagittal View
          ATOMmax teeth from behind
          Simple to Set Up and Easy to Use

          The Model 711-HN stand allows accurate phantom positioning. The included stand is adjustable in the x-y-z axes as well as allowing rotations about each of these axes. The head easily screws onto the stand and locks into place.

          ATOMmax phantom on stand

          Capabilities and Applications
          • Commission X-ray, panoramic X-ray, CT and cone beam CT systems
          • Learn how to properly position head for optimal images
          • Test reconstruction techniques and algorithms for implant planning and maxillofacial reconstruction
          • Train and evaluate personnel during implementation of new equipment and techniques
          • Validate consistency of image quality

          Specifications 
           
          Overall Size (Head Only Approximate)7.1" x 8.8" x 10.6"
          Phantom Weight11 lbs
          Stand Weight7 lbs
          Shipping weight29 lbs


          Ordering Information 
           
          Part No.QtyComponent Description
          711-HN1ATOM MAX Diagnostic Head Phantom
           1Positioning Stand w/ soft sided carrying case
           1Phantom Carrying Case

           

          德國QRM Micro-CT HA D32模體CT值校驗模體

          德國QRM Micro-CT HA D32模體CT值校驗模體,深圳市灣

          德國QRM Micro-CT HA D20模體CT值校驗模體

          德國QRM Micro-CT HA D20模體CT值校驗模體,深圳市灣

          R.D.Mathis美國進口AL2O3鍍氧化鋁蒸發(fā)舟

          氧化鋁涂層蒸發(fā)用于取代氧化鋁坩堝。這種蒸發(fā)舟的優(yōu)點是具有良好的熱導性,

          會員登錄

          ×

          請輸入賬號

          請輸入密碼

          =

          請輸驗證碼

          收藏該商鋪

          X
          該信息已收藏!
          標簽:
          保存成功

          (空格分隔,最多3個,單個標簽最多10個字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時間回復您~

          以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關企業(yè)負責,智能制造網(wǎng)對此不承擔任何保證責任。

          溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。

          在線留言
          乐山市| 肥城市| 洪雅县| 丰顺县| 巫山县| 福清市| 宁蒗| 德化县| 特克斯县| 德格县| 大田县| 海城市| 喀什市| 巩留县| 新余市| 商都县| 定安县| 曲阜市| 钟祥市| 漳州市| 育儿| 托克逊县| 保靖县| 泰顺县| 德兴市| 通海县| 三明市| 卢湾区| 元江| 宜君县| 乌苏市| 泸定县| 鱼台县| 张家口市| 潼南县| 潼南县| 南靖县| 封丘县| 迁安市| 囊谦县| 崇仁县|