          產(chǎn)品簡(jiǎn)介

          OmniScaniXUT這款儀器的設(shè)計(jì)目的是對(duì)航空航天制造業(yè)、汽車工業(yè)等的關(guān)鍵性工業(yè)部件、焊接部件進(jìn)行高速檢測(cè)

          詳細(xì)介紹

          OmniScan iX UT

          這款儀器的設(shè)計(jì)目的是對(duì)航空航天制造業(yè)、汽車工業(yè)等的關(guān)鍵性工業(yè)部件、焊接部件進(jìn)行高速檢測(cè)??烧系狡渌鼨z測(cè)系統(tǒng)中使用,通過(guò)GE DFO P3TF22、P3TF30、P3TF31和P3TF35驗(yàn)證。

          概覽:

          • Component testing

          • Aerospace manufacturing

          • Auto industry

          • Welded components

          • Integrated inspection systems

          • GE DFO P3TF22, P3TF30, P3TF31, and P3TF35 qualified

          Multichannel Ultrasonic Industrial Flaw Detector

          The OmniScan® iX is an industrial ultrasonic flaw detector system designed for the high-speed testing of critical industrial components.
          The compact OmniScan iX is housed in a rugged benchtop casing and is also available in a rack-mount version or with a swivel-arm assembly for easy integration into a production system.

          Designed with the Integrator in Mind

          The OmniScan iX is central to your industrial component testing system. Olympus provides all the software libraries required to enable the integrator to tie in your existing process control system.
          In addition, we provide the user interface ports necessary to connect a display, keyboard, mouse, and external storage. The real-time programmable alarm and analog outputs, and the encoder outputs, enable easy integration of the mechanical and electronic components of your industrial process.
          All that is needed for rapid and efficient component testing is built-in!

          Features

          • Data storage capability (internal and external)

          • Strip chart display

          • 16 real-time alarms

          • 16 real-time analog outputs (at PRF)

          • 4 digital inputs

          • Remote control from PC

          • Multiple A-scans

          • A-scan and C-scan imaging

          • 19-in., 5U rack-mount version

          • TomoView™-compatible for data analysis only

          • Remote control functions, for custom programming

          • 2-axis mechanical encoders

          • Multiple scan modes, including helicoidal

          • Multiple channels (up to 8)

          • TCG/DAC curves

          • Interface gate for immersion testing

          • Touch screen

          • VGA output

          • Maximum PRF is equal to the PRF divided by the number of channels (up to 12 kHz)

          • USB ports for keyboard, mouse, printer, and external storage

          • Back-wall echo attenuator (available at the end of 2006)

          OmniScan iX Benefits and Features

          Complete Integrated Solution

          • Affordable price

          • Rugged construction for industrial environment with rack-mount option

          • Remote control functions, for custom programming from PC

          • Optional data library to access A-scan and/or C-Scan on PC, for custom processing

          Software Features

          Strip Chart View

          • Each channel can have unique setups for multizone inspection.

          • Surface following interface gate

          • Built-in strip chart display and data storage

          • Multiple A-scans

          • A-scan and C-scan imaging

          • TCG curves

          • Multiple scan modes, including helicoidal

          • Back-wall echo attenuator (available at the end of 2006)

          • Monitoring of amplitude, peak position, crossing-level position, and thickness on each gate

          • Automatic gate synchronizes from previous gate for higher dynamic range of thickness.

          • A-scan data storage and C-scan postprocessing capabilities

          • Interface gate for surface following synchronization of measurement gate and/or TCG/DAC curves

          • Either positive or negative gate on RF signal (independent for each gate)

          • 16 alarms completely configurable on single-gate events or multiple-gate events, filter for n occurrences from one or multiple channels

          • Customizable color palette for amplitude and thickness C-scan

          • 60 Hz A-scan refresh rate with overlays of envelope and peak inside the gate

          Full-Featured C-Scan Software

          Hardware Features

          • Data storage (internal and external)

          • Multichannel configuration (up to 8 channels)

          • PRF up to 12 kHz / number of channels

          • Analog and alarm output compatibility with older systems

          • 16 real-time fully programmable alarms

          • 16 real-time analog outputs (at PRF)

          • 4 digital inputs to remotely control the machine

          • 2-axis mechanical encoders (option)

          • 2-axis mechanical encoder with data acquisition synchronization on mechanical movement

          Channel Configuration
          The OmniScan iX can be configured for pulse-echo, pitch-and-catch, or sequence firing.

          Component Testing
          Component testing is typically performed under an assembly-line environment. The OmniScan® iX is used to accept or reject (go-no-go testing) thousands of parts a day. Multichannel instrument configurations lend themselves very well to assembly-line applications, which are aimed at detecting flaws within the various zones of a part-not just under one particular area with one transducer. 16 alarm outputs on the OmniScan iX allow the tracking of a particular zone and monitoring the zone that is giving the alarm conditions.

          Engine-Disc Inspection
          Critical inspection of turbine engine discs requires a very sensitive ultrasonic flaw detector capable of detecting small defects in difficult nickel-based metals. Such instruments must be able to operate at high gains, with extremely low noise on both the A-scan display as well as the analog output. The OmniScan iX meets these very demanding requirements. Additional OmniScan iX features such as strip-chart recorder, C-scan display, and back-echo attenuator make this a very versatile instrument. The OmniScan iX can easily drop into existing, older test stations, then later transfer to a full functional station to perform on-board mapping/C-scan.

          The OmniScan iXhas been qualified by GE Aircraft Engines and added to the DFO as follows:

          • P3TF22 Longitudinal Immersion Ultrasonic Inspection of Forgings to Flat Bottom Hole Sensitivities

          • P3TF30 High Sensitivity Ultrasonic Inspection of Forged Fine Grain Powder Alloy

          • P3TF31 Ultrasonic Immersion Inspection of Powder Metallurgy Extruded Bars and Billets

          • P3TF35 Side Drill Hole Ultrasonic Inspection

          OmniScan iX Options

          Hardware Options
          OMNI-IX-A-RACK1: OmniScan iX rackmount bracket option
          OMNI-IX-A-SWIV: OmniScan iX swivel-arm assembly
          OMNI-IX-A-SCASE: OmniScan iX hard carrying case
          OMNI-IX-A-ACC1: OmniScan iX accessory kit includes the following:

          • 1 external keyboard,

          • 1 optical mouse,

          Software Options
          OMNI-IX-SO-ENC1: OmniScan iX software option to activate two encoder inputs on the instrument
          OMNI-IX-SO-BEA: OmniScan iX software option to activate back wall echo attenuator on the instrument

          Standard Inclusions

          • OmniScan iX instrument

          • Ethernet® cable

          • OmniScan software

          • User's manual

          • NDT Remote Control Software Library 2.0

          • 1 storage USB key


          技術(shù)規(guī)格:

          Overall dimensions (W × H × D)
          Benchtop version375 mm × 238 mm × 185 mm (14.75 in. × 9.4 in. × 7.3 in.)
          Rack mount version485 mm × 222 mm × 190 mm (19 in. × 8.7 in. × 7.5 in.)
          Weight6.5 kg (14.3 lb)
          ConnectorsBNC (2, 4 or 8)
          Pulser/Receiver
          Number of pulsers/receivers2, 4 or 8
          Pulser
          Pulse output50 V, 100 V, 200 V, 300 V ±10%
          Pulse widthAdjustable from 30 ns to 1000 ns ±10%, resolution of 2.5 ns
          Fall timeLess than 7 ns
          Pulse shapeNegative square wave
          Output impedanceLess than 7 Ω
          Receiver
          Receiver gain range0-100 dB, by steps of 0.1 dB
          Maximum input signal20 V p-p (screen at 128%)
          Minimum sensibility200 µV p-p (screen at 128%)
          Noise referred to input160 µV p-p (26 µV RMS) (128%)
          Input impedance50 Ω
          Input filter (99% bandwidth)Centered at 1 MHz (1.5 MHz), centered at 2 MHz (2.25 MHz), centered at 5 MHz (4 MHz), centered at 10 MHz (12 MHz), centered at 15 MHz, centered at 20 MHz, 0.25-2.5 MHz, 2-25 MHz BB
          Bandwidth of the system0.25-35 MHz (-3 dB)
          RectifierBoth, positive, negative, none
          ModePE (pulse-echo), PC (pitch-and-catch), TT (through-transmission). In P-P mode the maximum of number of pulsers equals the number of channels/2
          SmoothingDigital
          TCG
          Number of points16
          TCG rangeUp to 40 dB
          Maximum gain slope20 dB/µs
          Data acquisition
          A-scan acquisition rate6000 A-scans/s (PRF/N, where N = number of channels) (512-point A-scan)
          Maximum pulsing rate12 kHz (C-scan + Alarm mode). Up to 6 kHz with full A-scan recording
          Data processing
          Real-time averaging2, 4, 8, 16
          Gates
          Quantity3 : I (synchro), A and B (measure)
          SynchronizationI, A, B referenced on main bang, B referenced on gate I or A (post-synchronization)
          Data storage
          A-scan recording (TOFD)6000 A-scans/s (512-point A-scan) (3 MB/s transfer rate)
          C-scan type data recording10,000 (A1, A2, A3, T1, T2, T3) (3 gates)
          10 kHz (lower frequency for corrosion mapping)
          Data visualization
          Refresh rate60 Hz
          ModesA-scan, B-scan, C-scan, strip charts, multiple A-scans, and TOFD
          Data synchronization
          On time1 Hz-12 kHz
          On encoderOn 1 or 2 axes divided by 1 to 65,536 steps
          Outputs and inputs
          Number of alarms16 (programmable, hold time and delay, filters for n occurrences)
          ConditionsAny logical combination of gates
          SignalAmplitude or time of flight of gate A or B
          Analog outputs (at full PRF)16 (0 V to +5 V) (programmable for each gate)
          Digital inputs (DIN)4 programmable



          其他推薦產(chǎn)品更多>>

          感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

          智能制造網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.tzhjjxc.com,All rights reserved.

          以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

          會(huì)員登錄

          ×

          請(qǐng)輸入賬號(hào)

          請(qǐng)輸入密碼

          =

          請(qǐng)輸驗(yàn)證碼

          收藏該商鋪

          請(qǐng) 登錄 后再收藏

          提示

          您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~