          Overview

          SIMOTION D4x5-2 are drive-based Control Units for multi-axis systems. The individual variants essentially differ in terms of their PLC and motion control performance, memory size and interfaces. The main distinguishing features are:

          Distinguishing features 2)

          SIMOTION 
          D425-2 DP

          SIMOTION 
          D425-2 DP/PN

          SIMOTION 
          D435-2 DP

          SIMOTION 
          D435-2 DP/PN

          SIMOTION 
          D445-2 DP/PN

          SIMOTION 
          D455-2 DP/PN

          Performance class

          BASIC

          BASIC

          STANDARD

          STANDARD

          HIGH

          ULTRA-HIGH

          Maximum number of axes

          16

          16

          32

          32

          64

          128

          Available in SIPLUS version

          Second runtime level

          SERVOFast / IPOFast

          DRIVE-CLiQ interfaces

          4

          4

          6

          6

          6

          6

          Communication interfaces

                

          - PROFIBUS

          2

          2

          2

          2

          2

          2

          - PROFINET

          1 (3 ports) 1)

          1 (3 ports) 1)

          1 (3 ports) 1)

          1 (3 ports) 1)

          - Ethernet

          3

          2

          3

          2

          2

          2

           

          • Available

          – Not available

          1) Optional second PROFINET interface via CBE30-2 (4 ports)
          2) For further details such as cycle times, memory configuration, etc., refer to technical specifications

          The SIMOTION D425-2, D435-2, D445-2 and D455-2 Control Units feature PLC and motion control performance (open-loop control and motion control) for up to 16, 32, 64 or 128 axes, as required.

          The integrated drive control enables each D4x5-2 Control Unit to operate up to 6 servo, 6 vector or 12 V/f axes.

          The integrated drive control is based on the drive control of a SINAMICS S120 Control Unit CU320-2 (firmware version V4.x) and supports servo control (for a highly dynamic response), vector control (for maximum torque accuracy) and V/f control.

          SIMOTION D435-2 DP/PN and D455-2 DP/PN are also available as SIPLUS version for use under extremely difficult environmental conditions e.g. in toxic atmospheres (for details refer to technical specifications). As BasedOn products the SIPLUS versions have the same functionality as the standard modules and are configured in the same way.

          Extension of the drive computing performance

          The motion control performance of a SIMOTION D4x5-2 can be utilized in full by expanding the computing performance at the drive in two different ways:

          • SINAMICS S120 Control Units (e.g. CU320-2) can be connected together with further SINAMICS S120 drive modules via PROFIBUS or PROFINET.
          • The SIMOTION CX32-2 Controller Extension can be connected via DRIVE?CLiQ, This module is extremely compact and can control up to 6 servo, 6 vector or 12 V/f axes.

          Area of application

          Field of application for the SIMOTION D4x5?2 Control Units are applications with a large number of coordinated axes and short cycle times.

          Typical fields of application are:

          • Compact multi-axis machines
          • High-performance applications with short machine cycles
          • Compact machines
            • Including the complete machine control in the drive
            • With extensive connection possibilities for communication, HMI and I/O
          • Distributed drive concepts
            • Applications with a large number of axes
            • Synchronization of several SIMOTION D Control Units via distributed synchronous operation

          Design

          SIMOTION D425?2 DP (on left) and SIMOTION D435?2 DP/PN with CBE30?2 inserted (on right)

          Interfaces

          Display and diagnostics

          • LEDs to display operating states and errors
          • 3 measuring sockets
          • Service switch and mode selector
          • Diagnostics button

          Onboard I/Os

          • 12 digital inputs
          • 16 digital inputs/outputs (max. 16 as high-speed measuring inputs, max. 8 as high-speed output cams)

          Communication

          • 6 x DRIVE?CLiQ (4 × DRIVE?CLiQ for D425?2)
          • 2 x Industrial Ethernet (3 × Industrial Ethernet for D4x5?2 DP), of which one interface easily accessible on the module front
          • 2 x PROFIBUS DP
          • 1 x PROFINET IO
            (1 interface with 3 ports, with D4x5?2 DP/PN only)
          • 2 x USB

          Data backup

          • 1 x slot for SIMOTION CompactFlash card

          Additional interfaces

          • Terminals for 24 V electronics power supply

          Option modules

          With the TB30 Terminal Board, the SIMOTION D4x52 Control Units can be extended with 4 digital inputs, 4 digital outputs, 2 analog inputs and 2 analog outputs. The TB30 Terminal Board is plugged into the option slot on the Control Unit.

          Using the CBE30?2 Communication Board for PROFINET IO, it is possible to equip the SIMOTION D4x5?2 DP/PN Control Units with a second PROFINET interface with 4 ports.

          Applications for a second PROFINET interface:

          • 2 separate networks (e.g. one local and one higher-level network)
          • Address space can be doubled to 2 × 4 KB
          • Maximum number of connectable devices can be doubled to 2 × 64
          • Separation into a high-speed and a slow bus system/execution system in order to make efficient use of the controller's capacity (applies only to SIMOTION D435?2 DP/PN, D445?2 DP/PN and D455?2 DP/PN)
            • PROFINET onboard: SERVOFast and IPOFast
            • PROFINET via CBE30?2: SERVO / IPO / IPO2

          Note:

          The CBE30?2 cannot be used in SIMOTION D4x5?2 DP Control Units. If the CBE30?2 is used without SERVOFast and IPOFast, then both PROFINET interfaces are assigned to SERVO / IPO / IPO2.

          Assembly/Installation

          The SIMOTION D4x5?2 Control Units can be mounted in the control cabinet in one of three ways:

          • Mounting with spacers
          • Mounting without spacers (D425?2 and D435?2 only)
          • Mounting without spacers (external cooling, D445?2 and D455?2 only)

          With external air cooling, the cooling fins of the D445?2/D455?2 Control Unit are outside of the control cabinet. A seal (option) is required so that the Control Unit can be hermetically mounted in the rear cabinet panel.

          The SIMOTION D4x5?2 Control Units are supplied with pre-assembled spacers. These can be removed if necessary.

          Data storage/data backup

          The SIMOTION D4x5?2 Control Units store the retentive process data permanently in a manner that requires no maintenance (refer to technical data for memory size).

          The real-time clock is backed up for several days via a SuperCap. The backup time can be extended via a battery in the double fan/battery module.

          The double fan/battery module incl. battery is contained in the scope of supply of the SIMOTION D4x5?2.

          The runtime software, user data and user programs are stored retentively on the CompactFlash card (CF). The retentive process data of the Control Unit can also be stored on this CompactFlash card via system command, e.g. if spare parts are required.

          Extended execution system (SERVOFast / IPOFast)

          The SIMOTION D435?2 DP/PN, D445?2 DP/PN and D455?2 DP/PN Control Units have (in addition to SERVO, IPO and IPO2) an additional second runtime level (SERVOFast and IPOFast).

          The additional runtime level allows the distribution of electric and/or hydraulic axes with different dynamic responses on a slow and a fast bus system so that the performance of the controller can be used more efficiently.

          It also enables a particularly fast I/O processing in conjunction with high-speed PROFINET I/O modules.

          Thanks to the extended execution system, electrical positioning drives can be controlled with cycle times in the millisecond range requiring fewer resources and at the same time the pressure-controlled axes of an hydraulic press can be controlled with a high dynamic response and short cycle times.

          Closed-loop control of an hydraulic press with SERVOFast and IPOFast

          If SERVOFast and IPOFast are activated, the following assignment applies:

          • SERVOFast and IPOFast are assigned to the PROFINET.
          • SERVO, IPO and IPO2 are assigned to the PROFIBUS or the integrated drives of the SIMOTION D4x5?2/CX32?2.

          If a second PROFINET interface is provided by means of a CBE30?2, this will also be assigned to SERVO, IPO and IPO2. In this case, the onboard PROFINET interface is always assigned to SERVOFast und IPOFast.

          Connectable I/Os

          PROFINET IO:

          • Certified PROFINET devices
          • Distributed I/Os SIMATIC ET 200S/SP/M/MP/eco PN/pro
          • Drive systems (e.g. SINAMICS S110/S120)

          PROFIBUS DP:

          • Certified PROFIBUS standard slaves 
            (DP?V0, DP?V1, DP?V2)
          • SIMATIC ET 200S/SP/M/MP/eco/pro distributed I/Os
          • Drive systems (e.g. SINAMICS S110/S120)

          DRIVE?CLiQ:

          Modules from the SINAMICS S120 range:

          • TM15, TM17 High Feature Terminal Modules, TM31, etc.
          • SMC/SME Sensor Modules
          • DMC20/DME20 DRIVE?CLiQ Hub Module

          USB:

          The integrated USB interface allows, for example, a USB memory stick to be connected for a project or firmware update.

          Expansion with SINAMICS S120 drive modules

          SINAMICS S120 drive modules in booksize format (Line Modules, Motor Modules, etc.) are connected to the SIMOTION D4x5?2 Control Unit via DRIVE?CLiQ.

          SINAMICS S120 PM240-2 and PM340 Power Modules in blocksize format can be operated on the SIMOTION D4x5?2 Control Units with the CUA31/CUA32 Control Unit Adapters.

          Note:

          DRIVE?CLiQ cables which are required to connect Line/Motor Modules to SIMOTION D are supplied in a standard length with the Line/Motor Modules.

          Integration

          SIMOTION D4x5?2 Control Unit connection overview

          When dimensioning cables, you must always observe the maximum permissible cable lengths.

          If these maximum lengths are exceeded, malfunctions can occur.

          The permissible length of PROFIBUS DP cables depends on the configuration.

          The DRIVE?CLiQ cables used for the SINAMICS S120 CU320?2 Control Unit can also be used for SIMOTION D4x5?2 Control Units.

          For more information about signal cables, refer to chapter MOTION-CONNECT connection systems.

          Technical Specifications

          Order number

           

          6AU1425-2AA00-0AA0

          6AU1425-2AD00-0AA0

          6AU1435-2AA00-0AA0

          6AU1435-2AD00-0AA0

          6AU1445-2AD00-0AA0

          6AU1455-2AD00-0AA0

          product brand name

           

          SIMOTION

          SIMOTION

          SIMOTION

          SIMOTION

          SIMOTION

          SIMOTION

          Product type designation

           

          D425-2 DP

          D425-2 DP/PN

          D435-2 DP

          D435-2 DP/PN

          D445-2 DP/PN

          D455-2 DP/PN

          Performance class for motion control system

           

          BASIC Performance

          BASIC Performance

          STANDARD Performance

          STANDARD Performance

          HIGH Performance

          ULTRA-HIGH Performance

          Version of the motion control system

           

          Multiple-axis system

          Multiple-axis system

          Multiple-axis system

          Multiple-axis system

          Multiple-axis system

          Multiple-axis system

          PLC and motion control performance

           

           

           

           

           

           

           

          Number of axes maximum

           

          16

          16

          32

          32

          64

          128

          Minimum PROFIBUS cycle clock

          ms

          1

          1

          1

          1

          1

          1

          Minimum PROFINET send cycle clock

          ms

          --

          0.25

          --

          0.25

          0.25

          0.25

          Minimum servo cycle clock

          ms

          0.5

          0.5

          0.5

          0.25

          0.25

          0.25

          Minimum interpolator cycle clock

          ms

          0.5

          0.5

          0.5

          0.25

          0.25

          0.25

          Minimum servo cycle clock note

           

          --

          --

          --

          0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

          0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

          0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

          Integrated drive control

           

           

           

           

           

           

           

          Maximum number of axes for integrated drive control

           

           

           

           

           

           

           

          • ● servo

           

          6

          6

          6

          6

          6

          6

          • ● vector

           

          6

          6

          6

          6

          6

          6

          • ● V/f

           

          12

          12

          12

          12

          12

          12

          • ● note

           

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Memory

           

           

           

           

           

           

           

          RAM (work memory)

          Mbyte

          64

          64

          86

          86

          160

          320

          Additional RAM work memory for Java applications

          Mbyte

          20

          20

          20

          20

          20

          20

          RAM disk (load memory)

          Mbyte

          31

          31

          41

          41

          56

          76

          Retentive memory

          kbyte

          364

          364

          364

          364

          512

          512

          Persistent memory (user data on CF)

          Mbyte

          300

          300

          300

          300

          300

          300

          Communication

           

           

           

           

           

           

           

          DRIVE-CLiQ Interfaces

           

          4

          4

          6

          6

          6

          6

          USB Interfaces

           

          2

          2

          2

          2

          2

          2

          Industrial Ethernet Interfaces

           

          3

          2

          3

          2

          2

          2

          PROFIBUS Interfaces

           

          2

          2

          2

          2

          2

          2

          • ● note

           

          Equidistant and isochronous; Can be configured as master or slave

          Equidistant and isochronous; Can be configured as master or slave

          Equidistant and isochronous; Can be configured as master or slave

          Equidistant and isochronous; Can be configured as master or slave

          Equidistant and isochronous; Can be configured as master or slave

          Equidistant and isochronous; Can be configured as master or slave

          PROFINET Interfaces

           

          0

          1

          0

          1

          1

          1

          • ● note

           

          --

          1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

          --

          1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

          1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

          1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

          General technical data

           

           

           

           

           

           

           

          Fan

           

          Double fan/battery module included in scope of delivery

          Double fan/battery module included in scope of delivery

          Double fan/battery module included in scope of delivery

          Double fan/battery module included in scope of delivery

          Double fan/battery module included in scope of delivery

          Double fan/battery module included in scope of delivery

          DC supply voltage

           

           

           

           

           

           

           

          • ● rated value

          V

          24

          24

          24

          24

          24

          24

          • ● permissible range

          V

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          Consumed current typical

          mA

          700

          1 000

          700

          1 000

          1 900

          1 900

          • ● Note

           

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          Making current, typ.

          A

          5

          5

          5

          5

          5

          5

          Active power loss typical

          W

          17

          24

          17

          24

          46

          46

          Ambient temperature, during

           

           

           

           

           

           

           

          • ● long-term storage

          °C (°F)

          -25 ... +55 (-13 ... +131)

          -25 ... +55 (-13 ... +131)

          -25 ... +55 (-13 ... +131)

          -25 ... +55 (-13 ... +131)

          -25 ... +55 (-13 ... +131)

          -25 ... +55 (-13 ... +131)

          • ● transport

          °C (°F)

          -40 ... +70 (-40 ... +158)

          -40 ... +70 (-40 ... +158)

          -40 ... +70 (-40 ... +158)

          -40 ... +70 (-40 ... +158)

          -40 ... +70 (-40 ... +158)

          -40 ... +70 (-40 ... +158)

          • ● operation

          °C (°F)

          0 ... 55 (32 ... 131)

          0 ... 55 (32 ... 131)

          0 ... 55 (32 ... 131)

          0 ... 55 (32 ... 131)

          0 ... 55 (32 ... 131)

          0 ... 55 (32 ... 131)

          • — note

           

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Relative humidity during operation

          %

          5 ... 95

          5 ... 95

          5 ... 95

          5 ... 95

          5 ... 95

          5 ... 95

          Air pressure

          hPa

          620 ... 1 060

          620 ... 1 060

          620 ... 1 060

          620 ... 1 060

          620 ... 1 060

          620 ... 1 060

          Degree of protection

           

          IP20

          IP20

          IP20

          IP20

          IP20

          IP20

          Height

          mm (in)

          380 (14.96063)

          380 (14.96063)

          380 (14.96063)

          380 (14.96063)

          380 (14.96063)

          380 (14.96063)

          Width

          mm (in)

          50 (1.9685)

          50 (1.9685)

          50 (1.9685)

          50 (1.9685)

          50 (1.9685)

          50 (1.9685)

          Depth

          mm (in)

          270 (10.62992)

          270 (10.62992)

          270 (10.62992)

          270 (10.62992)

          270 (10.62992)

          270 (10.62992)

          • ● Note

           

          When the spacer is removed 230 mm (9.05 in) deep

          When the spacer is removed 230 mm (9.05 in) deep

          When the spacer is removed 230 mm (9.05 in) deep

          When the spacer is removed 230 mm (9.05 in) deep

          When the spacer is removed 230 mm (9.05 in) deep

          When the spacer is removed 230 mm (9.05 in) deep

          Net weight

          g (lb (avoirdupois))

          3 600 (7.93664)

          3 600 (7.93664)

          3 600 (7.93664)

          3 600 (7.93664)

          4 400 (9.70034)

          4 400 (9.70034)

          Digital inputs

           

           

           

           

           

           

           

          Number of digital inputs

           

          12

          12

          12

          12

          12

          12

          DC input voltage

           

           

           

           

           

           

           

          • ● rated value

          V

          24

          24

          24

          24

          24

          24

          • ● for signal "1"

          V

          15 ... 30

          15 ... 30

          15 ... 30

          15 ... 30

          15 ... 30

          15 ... 30

          • ● for signal "0"

          V

          -3 ... +5

          -3 ... +5

          -3 ... +5

          -3 ... +5

          -3 ... +5

          -3 ... +5

          Electrical isolation

           

          Yes

          Yes

          Yes

          Yes

          Yes

          Yes

          • ● note

           

          Yes, in groups of 6

          Yes, in groups of 6

          Yes, in groups of 6

          Yes, in groups of 6

          Yes, in groups of 6

          Yes, in groups of 6

          Current consumption for "1" signal level, typ.

          mA

          9

          9

          9

          9

          9

          9

          Input delay time for

           

           

           

           

           

           

           

          • ● signal "0" → "1", typ.

          µs

          50

          50

          50

          50

          50

          50

          • ● signal "1" → "0", typ.

          µs

          150

          150

          150

          150

          150

          150

          Digital inputs/outputs

           

           

           

           

           

           

           

          Number of digital I/Os

           

          16

          16

          16

          16

          16

          16

          Parameterization possibility of the digital I/Os

           

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          If used as an input

           

           

           

           

           

           

           

          DC input voltage

           

           

           

           

           

           

           

          • ● rated value

          V

          24

          24

          24

          24

          24

          24

          • ● for signal "1"

          V

          15 ... 30

          15 ... 30

          15 ... 30

          15 ... 30

          15 ... 30

          15 ... 30

          • ● for signal "0"

          V

          -3 ... +5

          -3 ... +5

          -3 ... +5

          -3 ... +5

          -3 ... +5

          -3 ... +5

          Electrical isolation

           

          No

          No

          No

          No

          No

          No

          Current consumption for "1" signal level, typ.

          mA

          9

          9

          9

          9

          9

          9

          Input delay time for

           

           

           

           

           

           

           

          • ● signal "0" → "1", typ.

          µs

          5

          5

          5

          5

          5

          5

          • ● signal "1" → "0", typ.

          µs

          50

          50

          50

          50

          50

          50

          Measuring input reproducibility

          µs

          5

          5

          5

          5

          5

          5

          Measuring input resolution

          µs

          1

          1

          1

          1

          1

          1

          If used as an output

           

           

           

           

           

           

           

          Load voltage

           

           

           

           

           

           

           

          • ● rated value

          V

          24

          24

          24

          24

          24

          24

          • ● permissible range

          V

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          20.4 ... 28.8

          Electrical isolation

           

          No

          No

          No

          No

          No

          No

          Current carrying capacity for each output, max.

          mA

          500

          500

          500

          500

          500

          500

          Leakage current, max.

          mA

          2

          2

          2

          2

          2

          2

          Output delay for

           

           

           

           

           

           

           

          • ● signal "0" → "1", typ.

          µs

          150

          150

          150

          150

          150

          150

          • ● signal "0" → "1", max.

          µs

          400

          400

          400

          400

          400

          400

          • ● signal "1" → "0", typ.

          µs

          75

          75

          75

          75

          75

          75

          • ● signal "1" → "0", max.

          µs

          150

          150

          150

          150

          150

          150

          • — note

           

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Cam output reproducibility

          µs

          10

          10

          10

          10

          10

          10

          Cam output resolution

          µs

          1

          1

          1

          1

          1

          1

          Switching frequency of the outputs for

           

           

           

           

           

           

           

          • ● resistive load, max.

          Hz

          100

          100

          100

          100

          100

          100

          • ● inductive load, max.

          Hz

          2

          2

          2

          2

          2

          2

          • ● lamp load, max.

          Hz

          11

          11

          11

          11

          11

          11

          Short-circuit protection

           

          Yes

          Yes

          Yes

          Yes

          Yes

          Yes

          Additional technical data

           

           

           

           

           

           

           

          Back-up of non-volatile data

           

           

           

           

           

           

           

          • ● of retentive data

           

          unlimited buffer duration

          unlimited buffer duration

          unlimited buffer duration

          unlimited buffer duration

          unlimited buffer duration

          unlimited buffer duration

          • ● of real-time clock, min.

          d

          4

          4

          4

          4

          4

          4

          • ● note

           

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          Approvals

           

           

           

           

           

           

           

          • ● USA

           

          cULus

          cULus

          cULus

          cULus

          cULus

          cULus

          • ● Canada

           

          cULus

          cULus

          cULus

          cULus

          cULus

          cULus

          • ● Australia

           

          C-Tick

          C-Tick

          C-Tick

          C-Tick

          C-Tick

          C-Tick

          • ● Korea

           

          KCC

          KCC

          KCC

          KCC

          KCC

          KCC

           

          Order number

           

          6AG1435-2AD00-4AA0

          6AG1455-2AD00-4AA0

          product brand name

           

          SIPLUS

          SIPLUS

          Product type designation

           

          D435-2 DP/PN SIPLUS

          D455-2 DP/PN SIPLUS

          Performance class for motion control system

           

          STANDARD Performance

          ULTRA-HIGH Performance

          Version of the motion control system

           

          Multiple-axis system

          Multiple-axis system

          PLC and motion control performance

           

           

           

          Number of axes maximum

           

          32

          128

          Minimum PROFIBUS cycle clock

          ms

          1

          1

          Minimum PROFINET send cycle clock

          ms

          0.25

          0.25

          Minimum servo cycle clock

          ms

          0.25

          0.25

          Minimum interpolator cycle clock

          ms

          0.25

          0.25

          Minimum servo cycle clock note

           

          0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

          0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

          Integrated drive control

           

           

           

          Maximum number of axes for integrated drive control

           

           

           

          • ● servo

           

          6

          6

          • ● vector

           

          6

          6

          • ● V/f

           

          12

          12

          • ● note

           

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

          Memory

           

           

           

          RAM (work memory)

          Mbyte

          86

          320

          Additional RAM work memory for Java applications

          Mbyte

          20

          20

          RAM disk (load memory)

          Mbyte

          41

          76

          Retentive memory

          kbyte

          364

          512

          Persistent memory (user data on CF)

          Mbyte

          300

          300

          Communication

           

           

           

          DRIVE-CLiQ Interfaces

           

          6

          6

          USB Interfaces

           

          2

          2

          Industrial Ethernet Interfaces

           

          2

          2

          PROFIBUS Interfaces

           

          2

          2

          • ● note

           

          Equidistant and isochronous; Can be configured as master or slave

          Equidistant and isochronous; Can be configured as master or slave

          PROFINET Interfaces

           

          1

          1

          • ● note

           

          1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

          1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

          General technical data

           

           

           

          Fan

           

          Double fan/battery module included in scope of delivery

           

          DC supply voltage

           

           

           

          • ● rated value

          V

          24

          24

          • ● permissible range

          V

          20.4 ... 28.8

          20.4 ... 28.8

          Consumed current typical

          mA

          1 000

          1 900

          • ● Note

           

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

          Making current, typ.

          A

          5

          5

          Active power loss typical

          W

          24

          46

          Ambient temperature, during

           

           

           

          • ● long-term storage

          °C (°F)

          -25 ... +55 (-13 ... +131)

          -25 ... +55 (-13 ... +131)

          • ● transport

          °C (°F)

          -40 ... +70 (-40 ... +158)

          -40 ... +70 (-40 ... +158)

          • ● operation

          °C (°F)

          0 ... 55 (32 ... 131)

          0 ... 55 (32 ... 131)

          • — note

           

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

          Relative humidity

           

           

           

          • ● during operation

          %

          0 ... 100

          0 ... 100

          • ● without condensation during operation maximum Note

           

          condensation/frost permitted (no commissioning in bedewed state)

          condensation/frost permitted (no commissioning in bedewed state)

          Conformal coating

           

          Yes

          Yes

          Resistance

           

           

           

          • ● to biologically active substances conformity acc. to EN 60721-3-3

           

          Yes

          Yes

          • — Note

           

          Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces!

          Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces!

          • ● to chemically active substances conformity acc. to EN 60721-3-3

           

          Yes

          Yes

          • — Note

           

          Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation.

          Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation.

          Air pressure

          hPa

          620 ... 1 060

          620 ... 1 060

          Degree of protection

           

          IP20

          IP20

          Height

          mm (in)

          380 (14.96063)

          380 (14.96063)

          Width

          mm (in)

          50 (1.9685)

          50 (1.9685)

          Depth

          mm (in)

          270 (10.62992)

          270 (10.62992)

          • ● Note

           

          When the spacer is removed 230 mm (9.05 in) deep

          When the spacer is removed 230 mm (9.05 in) deep

          Net weight

          g (lb (avoirdupois))

          3 600 (7.93664)

          4 400 (9.70034)

          Digital inputs

           

           

           

          Number of digital inputs

           

          12

          12

          DC input voltage

           

           

           

          • ● rated value

          V

          24

          24

          • ● for signal "1"

          V

          15 ... 30

          15 ... 30

          • ● for signal "0"

          V

          -3 ... +5

          -3 ... +5

          Electrical isolation

           

          Yes

          Yes

          • ● note

           

          Yes, in groups of 6

          Yes, in groups of 6

          Current consumption for "1" signal level, typ.

          mA

          9

          9

          Input delay time for

           

           

           

          • ● signal "0" → "1", typ.

          µs

          50

          50

          • ● signal "1" → "0", typ.

          µs

          150

          150

          Digital inputs/outputs

           

           

           

          Number of digital I/Os

           

          16

          16

          Parameterization possibility of the digital I/Os

           

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

          If used as an input

           

           

           

          DC input voltage

           

           

           

          • ● rated value

          V

          24

          24

          • ● for signal "1"

          V

          15 ... 30

          15 ... 30

          • ● for signal "0"

          V

          -3 ... +5

          -3 ... +5

          Electrical isolation

           

          No

          No

          Current consumption for "1" signal level, typ.

          mA

          9

          9

          Input delay time for

           

           

           

          • ● signal "0" → "1", typ.

          µs

          5

          5

          • ● signal "1" → "0", typ.

          µs

          50

          50

          Measuring input reproducibility

          µs

          5

          5

          Measuring input resolution

          µs

          1

          1

          If used as an output

           

           

           

          Load voltage

           

           

           

          • ● rated value

          V

          24

          24

          • ● permissible range

          V

          20.4 ... 28.8

          20.4 ... 28.8

          Electrical isolation

           

          No

          No

          Current carrying capacity for each output, max.

          mA

          500

          500

          Leakage current, max.

          mA

          2

          2

          Output delay for

           

           

           

          • ● signal "0" → "1", typ.

          µs

          150

          150

          • ● signal "0" → "1", max.

          µs

          400

          400

          • ● signal "1" → "0", typ.

          µs

          75

          75

          • ● signal "1" → "0", max.

          µs

          150

          150

          • — note

           

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

          Cam output reproducibility

          µs

          10

          10

          Cam output resolution

          µs

          1

          1

          Switching frequency of the outputs for

           

           

           

          • ● resistive load, max.

          Hz

          100

          100

          • ● inductive load, max.

          Hz

          2

          2

          • ● lamp load, max.

          Hz

          11

          11

          Short-circuit protection

           

          Yes

          Yes

          Additional technical data

           

           

           

          Back-up of non-volatile data

           

           

           

          • ● of retentive data

           

          unlimited buffer duration

          unlimited buffer duration

          • ● of real-time clock, min.

          d

          4

          4

          • ● note

           

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

          Approvals

           

           

           

          • ● USA

           

          cULus

          cULus

          • ● Canada

           

          cULus

          cULus

          • ● Australia

           

          C-Tick

          C-Tick

          • ● Korea

           

          KCC

          KCC

           

          Accessories

          Description

          Order No.

          Accessories for SIMOTION D4x5?2

          Double fan/battery module

          incl. battery

          Spare part for SIMOTION D4x5?2

          6FC5348-0AA02-0AA0

          Battery

          Spare part for fan/battery module

          6FC5247-0AA18-0AA0

          Seal for external air cooling

          (1 pack = 10 units)

          With external air cooling, the cooling fins of the Control Unit are outside of the control cabinet.

          A seal is required so that the D445?2/D455?2 can be hermetically mounted in the rear cabinet panel.

          6FC5348-0AA07-0AA0

          Accessories for PROFIBUS

          PROFIBUS RS485 bus connector with angular cable outlet (35°) and screw-type terminals

          Max. transmission rate 12 Mbit/s

           
          • Without PG interface

          6ES7972-0BA42-0XA0

          • With PG interface

          6ES7972-0BB42-0XA0

          PROFIBUS Fast Connect RS485 bus connector with angular cable outlet (35°) and insulation displacement terminals

          Max. transmission rate 12 Mbit/s

           
          • Without PG interface

          6ES7972-0BA60-0XA0

          • With PG interface

          6ES7972-0BB60-0XA0

          PROFIBUS adapter plug

          for raising the PROFIBUS connector to create more wiring space

          6FX2003-0BB00

          Accessories for PROFINET (interface X150)

          RJ45 FastConnect connector for Industrial Ethernet/PROFINET

          145° cable outlet 
          (10/100 Mbit/s)

           
          • 1 pack = 1 unit

          6GK1901-1BB30-0AA0

          • 1 pack = 10 units

          6GK1901-1BB30-0AB0

          • 1 pack = 50 units

          6GK1901-1BB30-0AE0

          FastConnect cables for Industrial Ethernet/PROFINET 1)

           
          • IE FC standard cable GP 2x2

          6XV1840-2AH10

          • IE FC flexible cable GP 2x2

          6XV1870-2B

          • IE FC trailing cable GP 2x2

          6XV1870-2D

          • IE FC trailing cable 2x2

          6XV1840-3AH10

          • IE FC marine cable 2x2

          6XV1840-4AH10

          Stripping tool for Industrial Ethernet/PROFINET FastConnect cables

           
          • IE FC stripping tool

          6GK1901-1GA00

          Accessory for Industrial Ethernet (interface X120, X127, X130)

          RJ45 FastConnect connector for Industrial Ethernet/PROFINET

          180° cable outlet 
          (10/100/1000 Mbit/s)

           
          • 1 pack = 1 unit

          6GK1901-1BB11-2AA0

          • 1 pack = 10 units

          6GK1901-1BB11-2AB0

          • 1 pack = 50 units

          6GK1901-1BB11-2AE0

          FastConnect cables for Industrial Ethernet/PROFINET 1)

           
          • IE FC Standard Cable GP 4x2

          6XV1878-2A

          • IE FC Flexible Cable GP 4x2

          6XV1878-2B

          Stripping tool for Industrial Ethernet/PROFINET FastConnect cables

           
          • IE FC stripping tool

          6GK1901-1GA00

          Other accessories

          Dust-proof blanking plugs

          (50 units) for sealing unused DRIVE?CLiQ, Ethernet and PROFINET ports

          6SL3066-4CA00-0AA0

           

          1) Sold by the meter; max. length 1000 m (3281 ft); minimum order 20 m (65.62 ft).

          More information

          More information

          • about PROFIBUS DP/MPI cables and MOTION?CONNECT can be found in chapter MOTION?CONNECT connection systems.
          • about PROFIBUS DP, Industrial Ethernet and PROFINET can be found in Catalog IK PI and the Industry Mall under Automation Technology/Industrial Communication as well as the chapter Communication.
          • about the ordering data for other SINAMICS drive components such as Line Modules, Motor Modules, DRIVE?CLiQ cables, etc. can be found in chapter SINAMICS S120 drive system and the Industry Mall under Drive Technology/Converters/....

          Integrated drive control

          The drive control integrated in the SIMOTION D4x5?2 Control Units is based on the drive control of a SINAMICS S120 CU320?2 Control Unit (firmware version V4.x), whereby there are minor functional differences. For example, the integrated drive control does not have a basic positioner function (EPos), since this is already covered by SIMOTION technology functions.

          For more information, refer to chapter System description – Dimensioning and the documentation for SIMOTION and SINAMICS.

          SIZER for Siemens Drives engineering tool

          With the SIZER for Siemens Drives engineering tool, you can easily configure the SINAMICS S110/S120 drive families including SIMOTION. It provides you with support for selecting and dimensioning the components for a Motion Control task. You can also determine the possible number of axes and the resulting utilization with SIZER for Siemens Drives in accordance with your performance requirements.

          For more information about SIZER for Siemens Drives, refer to chapter System description – Dimensioning.

          Connectors and cables

          The adapter plug (Order No. 6FX2003-0BB00) is required for D4x5?2 when the bus cable has to be looped through the left-hand PROFIBUS interface (X126; 2 PROFIBUS cables wired to the plug) and also

          • Ethernet interface X120, in the case of D4x5?2 DP or
          • Port 3 of the PROFINET interface X150 in the case of D4x5?2 DP/PN

          has to be wired to a FastConnect plug. With the adapter plug fitted, the PROFIBUS connector is higher which creates extra wiring space.

          Ethernet interfaces X120, X127 and X130 support 10, 100 and 1000 Mbit/s. For 1000 Mbit/s, 8?core cables (4x2) must be used as well as the 1000 Mbit version of the 180° FastConnect plug.

          The 145° FastConnect plugs cannot be used for Ethernet interface X130 (cable outlet downwards). They also only support a maximum of 100 Mbit/s.

          6ES73921BN000AA0西門子連接器

          6ES73921BN000AA0西門子連接器$r$n公司所售出的產(chǎn)品,

          西門子6ES73921BN000AA0連接器

          西門子6ES73921BN000AA0連接器$r$n公司所售出的產(chǎn)品,

          西門子連接器6ES73921BN000AA0

          西門子連接器6ES73921BN000AA0$r$n公司所售出的產(chǎn)品,

          會員登錄

          ×

          請輸入賬號

          請輸入密碼

          =

          請輸驗證碼

          收藏該商鋪

          X
          該信息已收藏!
          標簽:
          保存成功

          (空格分隔,最多3個,單個標簽最多10個字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時間回復(fù)您~

          以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,智能制造網(wǎng)對此不承擔任何保證責任。

          溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

          在線留言
          开化县| 当阳市| 岗巴县| 澄江县| 定远县| 晴隆县| 陇南市| 漳州市| 利辛县| 乳山市| 永安市| 黄冈市| 华亭县| 襄汾县| 东海县| 辰溪县| 米脂县| 宁阳县| 松溪县| 新密市| 桑日县| 开封县| 邢台市| 奉节县| 通辽市| 车险| 寿宁县| 浦城县| 墨竹工卡县| 元谋县| 应城市| 浦江县| 合川市| 东莞市| 虞城县| 丹凤县| 安塞县| 梁山县| 应用必备| 陆丰市| 连江县|