          PortSummarySerialPorts4RS-232/422/485portsEthernetSwitchPortsNPortS9450Iallcoppermodels:5RJ45copperportsNPortS9450Icopper/fibermodels:3RJ45copperports
           Port Summary
          Serial Ports4 RS-232/422/485 ports
          Ethernet Switch PortsNPort S9450I all copper models: 5 RJ45 copper ports
          NPort S9450I copper/fiber models: 3 RJ45 copper ports, 2 fiber ports
          Magnetic Isolation Protection1.5 kV built in
          Console Ports1 (10-pin RJ45 connector)
          • Physical Characteristics
          HousingMetal
          Weight2.54 kg (5.60 lb)
          Dimensions80 x 160 x 109 mm (3.15 x 6.30 x 4.29 in)
          • Environmental Limits
          Operating Temperature-40 to 85°C (-40 to 185°F)
          Storage Temperature-40 to 85°C (-40 to 185°F)
          Ambient Relative Humidity5 to 95% (non-condensing)
          • Power Requirements
          Input VoltageWV models: 24/48 VDC (18 to 72 VDC)
          HV models: 110/220 VAC/VDC (88 to 300 VDC, 85 to 264 VAC)
          Input Current520 mA @ 24 VDC
          80 mA @ 110 VDC
          • Standards and Certifications
          SafetyUL 508, UL 61010
          EMCEN 61000-6-2/61000-6-4
          EMICISPR 22, FCC Part 15B Class A
          EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
          IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
          IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
          IEC 61000-4-5 Surge: Power 6 kV; Signal: 4 kV
          IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
          IEC 61000-4-8
          Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D
          • Warranty
          Warranty Period5 years
          DetailsSee /warranty
          • Device Server Specifications
          • Serial Interface
          Number of Ports4
          Serial StandardsRS-232/422/485
          ConnectorDB9 male
          Serial Line Protection2 kV isolation protection
          RS-485 Data Direction ControlADDC® (Automatic Data Direction Control)
          Console PortDedicated RS-232 console port (10-pin RJ45)
          • Serial Communication Parameters
          Data Bits5, 6, 7, 8
          Stop Bits1, 1.5, 2
          ParityNone, Even, Odd, Space, Mark
          Flow ControlRTS/CTS and XON/XOFF
          Baudrate50 bps to 921.6 Kbps
          • Serial Signals
          RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
          RS-422Tx+, Tx-, Rx+, Rx-, GND
          RS-485-4wTx+, Tx-, Rx+, Rx-, GND
          RS-485-2wData+, Data-, GND
          Digital Input2 inputs with the same ground, but electrically isolated from the electronics• +13 to +30 V for state "1"
          • -30 to +3 V for state "0"
          • Max. input current: 8 mA
          • Software
          Configuration OptionsCommand Line Interface (CLI) through Serial/Telnet/SSH, Web Console (HTTP/HTTPS), Windows Utility
          Windows Real COM DriversWindows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
          Fixed TTY DriversSCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
          Linux Real TTY DriversLinux 2.4.x, 2.6.x, 3.x
          Operation ModesReal COM, TCP Server, TCP Client, UDP, RFC2217, Modbus, DNP3, DNP3 Raw Socket
          ManagementSNMP MIB-II, IEC 61850 MMS
          • Reliability
          Alert ToolsBuilt-in buzzer and RTC (real-time clock)
          Automatic Reboot TriggerBuilt-in WDT (watchdog timer)
          • MTBF (mean time between failures)
          Time347,436 hrs
          StandardTelcordia (Bellcore) Standard TR/SR
          • Ethernet Switch Specifications
          • Ethernet Interface
          StandardsIEEE 802.3 for 10BaseT
          IEEE 802.3u for 100BaseT(X) and 100BaseFX
          IEEE 802.3x for Flow Control
          IEEE 802.1D for Spanning Tree Protocol
          IEEE 802.1w for Rapid STP
          IEEE 802.1Q for VLAN Tagging
          IEEE 802.1p for Class of Service
          IEEE 802.1x for Authenti
          Network ProtocolsICMP, IPv4, TCP, UDP, ARP, Telnet, DNS, HTTP, SMTP, SNTP, IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, GMRP, LACP, RMON
          MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
          Flow ControlIEEE 802.3x flow control, back pressure flow control interface
          • Switch Properties
          Priority Queues4
          Max. Number of Available VLANs64
          VLAN ID RangeVID 1 to 4094
          IGMP Groups256
          CybersecurityReady for NERC CIP compliance system development• Supports IEC 62443 Level 2
          • Supports port access control list: MAC, 802.1x authentication
          • Supports RADIUS, TACACS+
          • Supports Syslog for system/event
          • Optical Fiber Interface

          • Switch Interface
          RJ45 Ports10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
          Alarm Contact2 relay outputs with current carrying capacity of 1A @ 24 VDC

          Available Models

           Model No.Description
          NPort S9450I-WV-T4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 24/48 VDC, -40 to 85°C operating temperature
          NPort S9450I-HV-T4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
          NPort S9450I-2M-SC-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
          NPort S9450I-2M-SC-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
          NPort S9450I-2M-ST-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
          NPort S9450I-2M-ST-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
          NPort S9450I-2S-SC-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
          NPort S9450I-2S-SC-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
          NPort S9450I-2S-ST-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
          NPort S9450I-2S-ST-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature

          NPort 5410/NPort 5430/NPort 5450串口聯(lián)

          特點(diǎn)和優(yōu)點(diǎn)為設(shè)置IP地址提供了簡(jiǎn)單易用的LCM(液晶模塊)界面自適應(yīng)1

          NPort 5110/NPort 5130/NPort 5150串口聯(lián)

          NPort 5110/NPort 5130/NPort 5150串口聯(lián)

          NPort® 5600系列串口聯(lián)網(wǎng)服務(wù)器

          特點(diǎn)和優(yōu)點(diǎn)簡(jiǎn)單易用的LCM(LiquidCrystalModule)顯

          會(huì)員登錄

          ×

          請(qǐng)輸入賬號(hào)

          請(qǐng)輸入密碼

          =

          請(qǐng)輸驗(yàn)證碼

          收藏該商鋪

          X
          該信息已收藏!
          標(biāo)簽:
          保存成功

          (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

          以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智能制造網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。

          溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

          在線留言
          广州市| 青海省| 汤原县| 磐石市| 浦北县| 丹东市| 沙洋县| 江城| 汉沽区| 孝感市| 大丰市| 眉山市| 斗六市| 视频| 淅川县| 若羌县| 泸水县| 洛扎县| 察雅县| 曲阜市| 南汇区| 阜平县| 衢州市| 涟源市| 梁平县| 攀枝花市| 招远市| 四平市| 铜鼓县| 罗定市| 读书| 和龙市| 临猗县| 博兴县| 逊克县| 姚安县| 琼结县| 团风县| 阿克| 金平| 麦盖提县|