精品乱码一区内射人妻无码-亚洲中文AⅤ中文字幕在线-免费不卡国产福利在线观看-国产综合无码一区二区色蜜蜜

          產(chǎn)品|公司|采購|資訊

          PD312型HART系列溫度變送器(帶現(xiàn)場顯示和傳感器)

          參考價面議
          具體成交價以合同協(xié)議為準
          • 公司名稱康寶萊儀表(珠海)有限公司
          • 品       牌
          • 型       號
          • 所  在  地
          • 廠商性質(zhì)
          • 更新時間2018/5/14 9:00:00
          • 訪問次數(shù)877
          產(chǎn)品標簽:

          在線詢價收藏產(chǎn)品 點擊查看電話

          聯(lián)系我們時請說明是 智能制造網(wǎng) 上看到的信息,謝謝!

          Description: HART? Temperature Transmitter with Display & Probe
          Inputs: Thermocouple, RTD, Ω & mV
          Power: Loop-Powered (10.5 to 45 VDC, reverse polarity protected)
          Display: Backlit LCD PV: 0.3" (8 mm)
          PD312型HART系列溫度變送器(帶現(xiàn)場顯示和傳感器) 產(chǎn)品信息




          I'd like to make an inquiry on this product


          FEATURES

          • Smart Temperature Transmitters
          • Universal Input: RTD, TC, Ohm & mV Inputs
          • Rugged General Purpose Models
          • 330° Rotatable Backlit LCD
          • Display PV, Input Type, Eng Units & Bargraph
          • Galvanic Isolation Prevents Ground Loops
          • Wide Voltage Range: 10.5 to 45 VDC
          • Wide Operating Temperature Range
          • Protection Heads & Thermowells Available
          • FM, CSA, ATEX, IECEx Explosion-Proof Enclosures
          • Order Factory Configured, Ready to Install*

          * Transmitters can also be compley configured using the ExSenseView PC software and modem. HART models can also be configured using a HART Communicator (with the exception of input Type and Units).

          INTRODUCTION

          The ExSense T Series is a line of rugged, smart temperature transmitters that includes models with HART communication capability. These models can be configured using a HART modem and a PC running the free HART software provided, or the range can be modified in the field using a handheld HART communicator. The other models can be configured using a USB modem and a PC running the free software provided. All models can be ordered with Pt100 RTD, J, K, T thermocouples; see Ordering Information for model numbers.


          PD301 - PD306 Head Mount Models

          The head mount models are offered as: hockey-puck only (PD301 & PD302) which can be mounted inside a DIN Form B connection head, pre-mounted in a connection head (PD303 & PD304), and pre-mounted in a connection head with temperature probe (PD305 & PD306). The PD302, PD304, and PD306 include HART communication capability. Standard enclosed models have an aluminum connection head with a 1/2" NPT conduit hole and 1/2" NPT process opening for a probe or adapter fitting, and are available with safe area (NEMA 4X, IP66 rated), or Certified explosion-proof housings. Non-standard models with other conduit hole and process opening sizes, as well as an optional stainless steel housing are available, visit the ExSense Builder.


          PD310 & PD312 Enhanced Display Models

          The enhanced display models, with standard loop-powered backlight, let the user see the display under any lighting condition, and present valuable information such as the process variable, input type, engineering units, and bargraph. The display can be configured to show the PV, mA output, or %. These models are housed in a sleek & rugged die-cast NEMA 4X enclosure that is available in general purpose and explosion-proof versions. The enclosure has two 1/2" NPT conduit holes, and one 1/2" NPT process sensor connection port for probe or adapter fitting. Non-standard models with other conduit hole and process opening sizes are available, see the ExSense Builder。 For remote mounting applications the PD310 may be ordered without the process sensor connection port.


          APPLICATIONS

          The ExSense packaging lends itself for duty in harsh environments. The good looking die-cast aluminum NEMA 4X housing affords serious protection from the elements, impact damage, corrosion, and electrical interference; it is also explosion-proof. It can be installed almost anywhere. The display models have very flexible installation options. The built-in mounting ears allow for wall, or pipe mounting, and include a rotatable meter. All ExSense systems can be also surface mounted via the thermowell.




          330° Rotatable LCD Display

          Mount the product at any convenient angle and rotate the internal display for best viewing angle.




          PD312 HART Transmitter & Remote Display

          In this application the Smart HART Explosion-Proof Temperature Transmitter is being powered by the PD6000 dual-scale meter; the meter displays the temperature on the top and the mA current on the bottom display. A PLC, DCS, or other devices could be connected in the loop as shown. The 250 ohm resistor is the minimum loop resistance needed for HART communication with a HART modem or a HART communicator.




          PD306 HART Head Transmitter ExSenseView PC Software & Remote Display

          In this application the Smart Transmitter is mounted in the explosion-proof connection head and is being powered by the PD6000 dual-scale meter. The HART communicator and HART modem are used during configuration or troubleshooting.

          CONFIGURATION

          PD301 - PD306 PC Configuration



          PD302 HART Configuration*



          PD310 & PD312 HART Configuration



          * Transmitters can be compley configured using the ExSenseView PC software and modem. HART models can also be configured using a HART Communicator (with the exception of input Type and Units).



          ExSenseView PC Software

          The Current Setup window is used to trim the analog output to match the device reading the current. Click on Read and type the values in the boxes. Click on Update to upload the new values to the transmitter. Test your loop by selecting a Fix Loop value and clicking Send.

          The Parameter Setup window is used to set up the input type, range for the 4-20 mA, temp units, and other settings related to the sensor and analog output. You can also select to display PV, mA, or %.

          The HART Information window allows you to configure or read the transmitter information and to modify the HART address.

          The Graph Monitor window is used to monitor the PV, mA,
          and %. You can also monitor just one of the variables. A log data file can be saved for later viewing; it contains the time, data value, and units. The screen update rate is selectable between 2 sec and 30 min.

          TRANSMITTER INPUT TYPES, RANGES, AND ACCURACY

          Input Type Transmitter Input Range Accuracy
          (% of Span)
          Min Output Span
          (4-20 mA)
          RTD Pt100 -200 to 850°C (-328 to 1562°F) ±0.08% (±0.2°C min) 10°C (18°F)
          Pt500 -200 to 250°C (-328 to 482°F) ±0.2% (±0.5°C min) 10°C (18°F)
          Pt1000 -200 to 250°C (-328 to 482°F) ±0.12% (±0.3°C min) 10°C (18°F)
          Cu50 -50 to 150°C (-58 to 302°F) ±0.08% (±0.2°C min) 10°C (18°F)
          Cu100 -50 to 150°C (-58 to 302°F) ±0.12% (±0.3°C min) 10°C (18°F)
          Ni100 -60 to 180°C (-76 to 356°F) ±0.08% (±0.2°C min) 10°C (18°F)
          Ni500 -60 to 180°C (-76 to 356°F) ±0.20% (±0.5°C min) 10°C (18°F)
          Ni1000 -60 to 150°C (-76 to 302°F) ±0.12% (±0.3°C min) 10°C (18°F)
          Potentiometer Resistance 0 to 400 Ω ±0.08% (±0.1 Ω min) 10 Ω
          0 to 2,000 Ω ±0.12% (±1.5 Ω min) 100 Ω
          TC B 0 to 1820°C ( 32 to 3308°F) ±0.08% (±2.0°C min) 500°C (900°F)
          E -270 to 1000°C (-454 to 1832°F) ±0.08% (±0.5°C min) 50°C (90°F)
          J -210 to 1200°C (-346 to 2192°F) ±0.08% (±0.5°C min) 50°C (90°F)
          K -270 to 1372°C (-454 to 2501°F) ±0.08% (±0.5°C min) 50°C (90°F)
          N -270 to 1300°C (-454 to 2372°F) ±0.08% (±1.0°C min) 50°C (90°F)
          R -50 to 1768°C ( -58 to 3214.4°F) ±0.08% (±2.0°C min) 500°C (900°F)
          S -50 to 1768°C ( -58 to 3214.4°F) ±0.08% (±2.0°C min) 500°C (900°F)
          T -270 to 400°C (-454 to 752°F) ±0.08% (±0.5°C min) 50°C (90°F)
          C 0 to 2320°C (32 to 4208°F) ±0.08% (±0.5°C min) 50°C (90°F)
          D 0 to 2320°C (32 to 4208°F) ±0.08% (±0.5°C min) 50°C (90°F)
          Voltage mV -10 to 75 mV ±0.08% (±20µV min) 5 mV
          -100 to 100 mV ±0.08% (±20µV min) 5 mV
          -100 to 500 mV ±0.08% (±30µV min) 6 mV
          -100 to 2000 mV ±0.08% (±50µV min) 20 mV


          COMPLETE TEMPERATURE ASSEMBLY

          Simplify your ordering process by getting a complete temperature assembly from Precision Digital. Use the online ExSense Builder to select your transmitter, temperature probe, and thermowell; specify the temperature range and you will get all the parts needed for your temperature system. Avoid the headaches of getting components that do not match, from different suppliers. Order a complete temperature assembly from Precision Digital and make your life easier.




           

          ACCESSORIES

          RTD Probes & Thermowells



          RTD probes are offered in 6", 9", and 12" lengths and ¼" diameter; other sizes are available upon request. Spring-loaded probes and thermowells are special order; please consult the factory for details.




          TC & RTD Connection Heads

          • General Purpose & Explosion-Proof
          • Aluminum & Stainless Steel
          • NEMA 4X, IP66 Rated
          • Stainless Steel Ball Chain
          • Spring-Loaded 2" Ceramic Block Available

          CONNECTIONS

          PD301 - PD306



          PD310 & PD312



          DIMENSIONS

          PD301 & PD302



          PD310 & PD312



          Thermowell Type T1

          PD303 & PD304




          MOUNTING










          SPECIFICATIONS

          General

          Input: Universal RTD, TC, Resistance, or Voltage
          Power Supply: 7.5 to 45 VDC, reverse polarity protected
          Storage Temperature: -40 to 100°C
          Connections: Screw terminals accept 12 to 22 AWG
          Output: Two-wire 4-20 mA scalable
          Accuracy: ±0.08% of span typical, see table on page 5 for details
          Temperature Drift: RTD: ±0.004°C/°C; TC: ±0.03°C/°C
          Underrange: 3.8 mA
          Overrange: 20.8 mA
          Sensor Break: Selectable ≤3.6 mA Low Alarm or ≥22 mA High Alarm
          Response Time: 1 second
          Long Term Stability: Better than 0.05% per year
          Start Up Time: Less than 5 seconds
          Noise Filter: Configurable from 0 to 85 µA
          Damping Time: Configurable from 0 to 30 sec
          Output Resolution: 0.3 µA
          Non-Volatile Memory: All configured settings are stored in non-volatile memory for a minimum of ten years.
          Relative Humidity: 0 to 90%, condensation allowed
          Isolation: 2 kV input-to-output
          Shock & Vibration Resistance: 4g/2 to 150 Hz as per IEC 60 068-26
          EMC: Immunity & emission interference according to GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
          Warranty: 1 year parts & labor


          PD310 & 312 Exp-Proof Smart Transmitter

          Display: PV: 0.3" (8 mm) 5-digit LCD, Input & Units: 0.2" (5 mm)
          Bargraph: 52 segments with 2% resolution
          Backlight: Loop-powered, always on
          Configuration Method: PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
          Load Impedance: 650 Ω @ 24 VDC max or ((V supply - 10.5 V)/0.0208 A) Ω
          Operating Temperature: -30 to 75°C
          Enclosure: Explosion-proof or general purpose die-cast aluminum, 0.3% max copper content, NEMA 4X, IP66; two ½" NPT conduit holes, one ½" NPT process connection; other sizes available upon request.
          PD310-A2 & PD312-A2 Approvals: FM: Explosion-proof for Class I, Division 1, Groups B, C and D; dust-ignition-proof for Class II/III, Division 1, Groups E, F and G, hazardous (classified) locations, indoors and outdoors (Type 4X/IP66)
          CSA: Explosion-proof for Class I, Division 1, Groups B, C and D; dust-ignition-proof for Class II/III, Division 1, Groups E, F and G, hazardous (classified) locations, indoors and outdoors (Type 4X/IP66)
          ATEX: II 2 G D, Ex d IIC, Ex tD A21, IP68, Ta = -40°C to +85°C
          IECEx: Ex d IIC, Ex A21 tD, IP68, Ta = -40°C to +85°C
          Weight: 2.42 lb (1.10 Kg)
          Overall Dimensions: 4.30" x 4.27" x 3.62" (109.2 x 108.4 x 92.0) (W x H x D), probe and thermowell not included


          PD301 & 302 Head Mount Smart Transmitter

          Configuration Method:
              PD301: PDA8301 USB modem and PC software
              PD302: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
          Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω
          Operating Temperature: -40 to 85°C
          Enclosure: Polycarbonate housing with epoxy potting, NEMA 1, IP00 (NEMA 4X, IP66 with PDA1080WM)
          Weight: 1.18 oz (33.5 g)
          Overall Dimensions: Dia. 1.73" x 0.89" (44 mm x 22.5 mm)
          Installation Angle: No limit
          Installation Area: Connection head according to DIN 43 729 Form B


          PD303 & PD304 Head-Mounted Smart Transmitter

          Configuration Method:
              PD303: PDA8301 USB modem and PC software
              PD304: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
          Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω
          Operating Temperature: -40 to 85°C
          Enclosure: Aluminum or 316 SS mounting head NEMA 4X, IP66 with optional explosion-proof Certification. Note: The Certification applies to the connection head only and not to the transmitter assembly.
          Weight: 1.0 lb (453.6 g)
          Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm)
          Installation Angle: No limit
          Installation Area: Connection head according to DIN 43 729 Form B


          PD305 & PD306 Head-Mounted Smart Transmitter with Thermowell and/or Probe

          Configuration Method:
              PD305: PDA8301 USB modem and PC software
              PD306: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator*
          Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω
          Operating Temperature: -40 to 85°C
          Enclosure: Aluminum or 316 SS mounting head NEMA 4X, IP66 with optional explosion-proof Certification
          Weight: 1.0 lb (453.6 g) plus probe/thermowell weight
          Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm) plus probe/thermowell length
          Installation Angle: No limit
          Installation Area: Connection head according to DIN 43 729 Form B
          * The Input Type and Units cannot be changed with HART Communicators (e.g. HC275, HC375).


          Connection Heads

          Material: Die-cast aluminum or 316 stainless steel
          Certification: FM/CSA/ATEX Explosion-proof Certified, NEMA 4X, IP66 or general purpose without certification
          Connections: Two ½" NPT for conduit and process connection; other sizes available upon request
          Mounting Holes: Accept M4 screws, see dimensions drawing
          Surface Finishing: Aluminum: Blue epoxy coated,
              Stainless steel: Electropolished
          O-Ring: Buna-N
          Weight: Aluminum: 0.450 kg (1.0 lb), Stainless steel: 0.90 kg (2.0 lbs)
          Features: SS ball chain included, terminal block (Ceramic/Bakelite optional)
          Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm)


           

          ExSense Builder



          To help build the correct model number for your application, use the online ExSense Builder. This online tool can be accessed by clicking on any of the links provided.
          After a transmitter type selection is made the following options are available:












          Options Availability
          Configuration Setup
          C0: Factory Default
          C1: Custom Configuration
          C2: Custom Configuration with Certificate of Calibration
          All transmitter types
          Enclosure
          A2: Exp-Proof Aluminum Enclosure, ½" NPT
          G2: Safe Area Aluminum Enclosure, ½" NPT
          S2: Exp-Proof Stainless Steel, ½" NPT
          Note: Additional conduit & process connections are available upon request.
          All, except PD301 & PD302

          Note: Stainless steel enclosure option is not available with PD310 or PD312
          Temperature Probe (¼" diameter)
          P11R04: Pt100 RTD 3-Wire, 4" Rigid Probe, 0.385
          P11R06: Pt100 RTD 3-Wire, 6" Rigid Probe, 0.385
          P11R09: Pt100 RTD 3-Wire, 9" Rigid Probe, 0.385
          P11R12: Pt100 RTD 3-Wire, 12" Rigid Probe, 0.385
          P11S04: Pt100 RTD 3-Wire, 4" Spring-Loaded, 0.385
          P11S06: Pt100 RTD 3-Wire, 6" Spring-Loaded, 0.385
          P11S09: Pt100 RTD 3-Wire, 9" Spring-Loaded, 0.385
          P11S12: Pt100 RTD 3-Wire, 12" Spring -Loaded, 0.385
          Note: Additional sensors and probe sizes are available upon request.
          PD305, PD306, PD312
          Thermowell
          T104: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 4" Probe
          T106: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 6" Probe
          T109: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 9" Probe
          T112: Thermowell Stepped Stem ½ NPT x ¾ NPT 316SS for 12" Probe
          PD305, PD306, PD312 with S06, S09, S12 options
          Note: If the product requires a temperature sensor, select a picture showing a temperature probe, the ExSense Builder will include the steps to select the temperature sensor.

          Note: Standard RTD is 1/4" in diameter , stainless steel, 400°F max. For other sizes and temperature ranges, contact the factory.

          Once a new model is generated using the ExSense Builder, you will
          1. see the price of the full model number built
          2. have the opportunity to purchase the product
          3. have the ability to us, yourself, or a third person the model number built

          Note: HART models must be configured using the ExSenseView PC software and PDA8302 HART modem. The Input Type and Units cannot be changed with HART Communicators (e.g. HC275, HC375).

          Go to the ExSense Builder to build a complete model number and get pricing.

          Example 1: PD301-C0 Head mount temperature transmitter with factory defaults
          Example 2: PD310-G2-C1 HART temperature transmitter with display, general purpose, custom configuration
          Example 3: PD312-G2-C1-P11S06-T106
          PD312 = HART temperature transmitter with display & temperature probe
          G2 = Rugged general purpose NEMA 4X enclosure
          C1 = Custom configuration
          P11 = 100 Pt RTD with 6" leads
          S06 = Spring-loaded 6" probe for thermowell installation
          T106 = Type 1 thermowell to match 6" spring-loaded probe


          Example of Other Options:
          • C0 = Factory default configuration
          • A2 = Explosion-proof die-cast aluminum enclosure
          • C2 = Custom configuration with Certificate of Calibration
          • R06 = 6" Rigid probe

          RTD/TC Connection Head Assembly
          PDA1080WM head shown with PDA8059-04-EG terminal block
          在找 PD312型HART系列溫度變送器(帶現(xiàn)場顯示和傳感器) 產(chǎn)品的人還在看
          返回首頁 產(chǎn)品對比

          提示

          ×

          *您想獲取產(chǎn)品的資料:

          以上可多選,勾選其他,可自行輸入要求

          個人信息:

          Copyright gkzhan.com , all rights reserved

          智能制造網(wǎng)-工業(yè)4.0時代智能制造領(lǐng)域“互聯(lián)網(wǎng)+”服務(wù)平臺

          對比欄



          航空| 安康市| 双流县| 绥芬河市| 奉新县| 荔浦县| 都江堰市| 浙江省| 蒲江县| 桐柏县| 高雄市| 潍坊市| 新邵县| 温州市| 蒙自县| 临沧市| 图木舒克市| 芒康县| 肃宁县| 宣威市| 普安县| 禹州市| 徐州市| 玉溪市| 图们市| 炎陵县| 库伦旗| 泸州市| 塘沽区| 安塞县| 栾城县| 苗栗县| 鹰潭市| 望谟县| 崇信县| 筠连县| 梁山县| 综艺| 漳浦县| 贵定县| 安丘市|