These load cells are extremely Slim and lightweight. Easy installation with hole in center. Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects. Protection Class IP67. CAP | ΦA | ΦB | ΦC | D | E | 50kgf | 10 | 55 | 22 | 15 | 2 | 100kgf | 200kgf | 500kgf | 1tf | 12 | 68 | 28 | 20 | 2 | 2tf | 3tf | 5tf | 10tf | 50 | 148 | 80 | 37 | 5 | 20tf | 70 | 155 | 99 | 43 | 5 | 30tf | 50tf | 100tf | 110 | 198 | 129 | 43 | 5 | 150tf | 165 | 278 | 200 | 50 | 8 | 200tf | 170 | 308 | 212 | 65 | 10 | |
| | Specifications | Accuracy | Rate | capacity (R.C) | 50kgf, 100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 30tf, 50tf, 100tf, 150tf, 200tf 490.3N, 980.7N, 1.961KN, 4.903KN, 9.807KN, 19.61KN, 29.42KN, 49.03KN, 98.07KN, 196.1KN, 490.3KN, 980.7KN, 1.961MIN | output (R.O) | 1.5mv/v±0.4% | Nonlinearity | 1% of R.O. | Repeatability | 0.5% of R.O. | Zero balance | 0.5% of R.O. | Temperature effect | on rated output | 0.05% of LOAD/10℃ | on zero balance | 0.1% of R.O./10℃ | Temperature range, compensated | -10~50℃ | Terminal resistance | input | 700 ±10Ω | output | 700 ±5Ω | Insulation resistance bridge | 2000MΩ | Excitation recommended | 10V | Safe overload | 150% R.C | Cable length | Φ7mm 4core, 5m | | | |